Intel H2000JF Technical Product Specification

Intel H2000JF Manual

Intel H2000JF manual content summary:

  • Intel H2000JF | Technical Product Specification - Page 1
    Intel® Server Board S2600JF Technical Product Specification Intel order number G31608-004 Revision 1.3 July 2012 Enterprise Platforms and Services Division - Marketing
  • Intel H2000JF | Technical Product Specification - Page 2
    Intel® Server Board S2600JF TPS Date December, 2011 February, 2012 May, 2012 July, 2012 Revision History Revision Number 1.0 1.1 1.2 1.3 Initial release. Modifications Added BMC sensor table and features.  Updated Design Specifications and ASHRAE specification.  Added NTB support in BIOS
  • Intel H2000JF | Technical Product Specification - Page 3
    Placement 6 2.1.2 Server Board Mechanical Drawings 7 3. Product Architecture Overview 8 3.1 High Level Product Features 8 3.2 Processor Support 10 3.2.1 Processor Socket Assembly 10 3.2.2 Processor Population Rules 11 3.3 Processor Function Overview 13 3.3.1 Intel® QuickPath
  • Intel H2000JF | Technical Product Specification - Page 4
    Table of Contents Intel® Server Board S2600JF TPS 3.5.2 Quad Small Form-factor Pluggable (QSFP) connector 33 3.6 Integrated Baseboard Management Controller Overview 34 3.6.1 Super I/O Controller 35 3.6.2 Graphics Controller and Video Support 36 3.6.3 Remote KVM...37 4. Platform
  • Intel H2000JF | Technical Product Specification - Page 5
    Intel® Server Board S2600JF TPS Table of Contents 4.14 Management Engine (ME 60 4.14.1 Overview ...60 4.14.2 BMC - Management Engine (ME) Distributed Model 60 4.14.3 ME System Management Bus (SMBus*) Interface 61 4.14.4 BMC - Management Engine Interaction 61 4.14.5 ME Power and Firmware
  • Intel H2000JF | Technical Product Specification - Page 6
    Table of Contents Intel® Server Board S2600JF TPS 7.4.3 NIC Connectors 131 7.4.4 Processor Thermal Design Power (TDP) Support 140 10. Power Supply Specification Guidelines 141 10.1 Power Supply DC Output Connector 141 10.2 Power Supply DC Output Specification 141 10.2.1 Output Power
  • Intel H2000JF | Technical Product Specification - Page 7
    Intel® Server Board S2600JF TPS Table of Contents 10.2.14 Ripple/Noise...143 10.2.15 Timing Requirement 143 Appendix A: Integration and Usage Tips 146 Appendix B: Integrated BMC Sensor Tables 147 Appendix C: BIOS Sensors and SEL Data 162 Appendix D: POST Code LED Decoder 169 Appendix E: Video
  • Intel H2000JF | Technical Product Specification - Page 8
    Figure 1. Intel® Server Board S2600JF (InfiniBand* SKU 3 Figure 2. Intel® Server Board S2600JF components 5 Figure 3. Rear Panel Connector Placement 6 Figure 4. Baseboard and Mounting holes 7 Figure 5. Intel® Server Board S2600JF Functional Block Diagram 9 Figure 6. Processor Socket Assembly
  • Intel H2000JF | Technical Product Specification - Page 9
    Intel® Server Board S2600JF TPS List of Figures Figure 39. Hard Disk Order Screen 108 Figure 40 47. Rear Panel Diagnostic LEDs (Block A 136 Figure 48. Turn On/Off Timing (Power Supply Signals 145 Figure 49. Diagnostic LED Placement Diagram 169 Revision 1.3 ix Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 10
    List of Tables Intel® Server Board S2600JF TPS List of Tables Table 1. Intel® Server Board S2600JF Feature Set 3 Table 2. Intel® Server Board S2600JF Features 8 Table 3. Mixed Processor Configurations 12 Table 4. UDIMM Support Guidelines 16 Table 5. RDIMM Support Guidelines 16 Table 6.
  • Intel H2000JF | Technical Product Specification - Page 11
    Intel® Server Board S2600JF TPS List of Tables Table 40. Setup Utility - System Acoustic and Performance Configuration Screen Fields ........94 Table 41. Setup Utility - Security Configuration Screen Fields 96 Table 42. Setup Utility - Server Management Configuration Screen Fields 98 Table 43.
  • Intel H2000JF | Technical Product Specification - Page 12
    Intel® Server Board S2600JF TPS Table 81. Chassis Intrusion Header (J6C1 134 Table 82. Network link/activity LED 135 Table 83. InfiniBand* link/activity LED 136 Table 84. Server Board Design Specifications 137 Table 85. Power Supply DC Power Table 149 Table 93. BIOS Sensor and SEL Data 162
  • Intel H2000JF | Technical Product Specification - Page 13
    Intel® Server Board S2600JF TPS List of Tables Revision 1.3 xiii Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 14
    Intel® Server Board S2600JF is a half width, dual sockets server board using the Intel® Xeon® Processor E5-2600 series processor, in combination with Intel® C600 chipset to provide an outstanding feature set for high performance and high density computing. This Technical Product Specification (TPS
  • Intel H2000JF | Technical Product Specification - Page 15
    Intel® Server Board S2600JF TPS 1.2 Server Board Use Disclaimer Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel® ensures through its own chassis development and testing that when Intel® server
  • Intel H2000JF | Technical Product Specification - Page 16
    hardware configuration:  S2600JF: Base SKU  S2600JFQ: Base SKU with InfiniBand* CX3 QDR populated  S2600JFF: Base SKU with InfiniBand* CX3 FDR populated The following table provides a high-level product feature list: Table 1. Intel® Server Board S2600JF Feature Set Feature Processors Memory
  • Intel H2000JF | Technical Product Specification - Page 17
    Server Board Overview Intel® Server Board S2600JF TPS Feature External I/O Connections Internal I/O connectors/headers Power Connections System Fan Support Add-in Riser Support Video Hard Drive Support RAID Support Server Management Description  DB-15 Video connectors  Two RJ-45 Network
  • Intel H2000JF | Technical Product Specification - Page 18
    Intel® Server Board S2600JF TPS Server Board Overview 2.1 Server Board Connector and Component Layout The following illustration provides a general overview of the server board, identifying key feature and component locations. The majority of the items identified are common in the Intel® Server
  • Intel H2000JF | Technical Product Specification - Page 19
    Server Board Overview Intel® Server Board S2600JF TPS 2.1.1 Board Rear Connector Placement The Intel® Server Board S2600JF has the following board rear connector placement: Description A NIC port 1 (RJ45) B NIC port 2 (RJ45) C DB15 video out D ID LED Description E Status LED F Dual port USB
  • Intel H2000JF | Technical Product Specification - Page 20
    Intel® Server Board S2600JF TPS Server Board Overview 2.1.2 Server Board Mechanical Drawings The following figure is a mechanical drawing for the Intel® Server Board S2600JF: Figure 4. Baseboard and Mounting holes Revision 1.3 7 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 21
    and high-density computing. 3.1 High Level Product Features Table 2. Intel® Server Board S2600JF Features Board Form Factor CPU Socket Chipset Memory Slots Ethernet InfiniBand* Storage SAS SW RAID Processor Support Video iSMS Chassis Power Supply S2600JF 6.4" (153mm) x 17.8" (453mm) Socket R, LGA
  • Intel H2000JF | Technical Product Specification - Page 22
    Intel® Server Board S2600JF TPS Product Architecture Overview DDR-3 MEMORY (800/1066/1333/1600Mhz) CPU 1 CPU 2 DDR-3 MEMORY (800/1066/1333/1600Mhz) CHANNEL 3 CHANNEL 2 CHANNEL 1 CHANNEL 0 Intel® Xeon® E5-2600 QPI PORT 0: 8.0GT/s QPI PORT 1: 8.0GT/s Intel® Xeon® E5-2600 CHANNEL 3 CHANNEL 2
  • Intel H2000JF | Technical Product Specification - Page 23
    Intel® Server Board S2600JF TPS 3.2 Processor Support The server board includes two Socket-R (LGA 2011) processor sockets and can support one or two of the Intel® Xeon® processor E5-2600 product family, with a Thermal Design Power (TDP) of up to 135W processor: The Intel® Xeon™ E5-2600 processor
  • Intel H2000JF | Technical Product Specification - Page 24
    TPS Product Architecture Overview Figure 7. Processor Socket ILM Variations The square ILM has a 90.5 x 90.5mm heat sink mounting hole pattern and is used on the Intel® Server Board S2600JF. 3.2.2 Processor Population Rules Note: Although the server board does support dual-processor configurations
  • Intel H2000JF | Technical Product Specification - Page 25
    Product Architecture Overview Intel® Server Board S2600JF TPS Table 3. Mixed Processor Configurations Error Processor family not identical Severity Fatal Processor cache not identical Fatal Processor frequency (speed) Major not identical System Action The BIOS detects the error condition and
  • Intel H2000JF | Technical Product Specification - Page 26
    Intel® Server Board S2600JF TPS Product Architecture Overview 3.3 Processor Function Overview With the release of the Intel® Xeon® processor E5-2600 product family, several key system components, including the CPU, Integrated Memory Controller (IMC), and Integrated IO Module (IIO), have been
  • Intel H2000JF | Technical Product Specification - Page 27
    Product Architecture Overview Intel® Server Board S2600JF TPS 3.3.1 Intel® QuickPath Interconnect The Intel® QuickPath Interconnect is a high speed, packetized, point-to-point interconnect used in the processor. The narrow high-speed links stitch together processors in distributed shared memory
  • Intel H2000JF | Technical Product Specification - Page 28
    Intel® Server Board S2600JF TPS Product Architecture Overview  DDR3 standard I/O Voltage of 1.5V for all speed  DDR3 Low Voltage of 1.35V for 1333MT/s or below  1Gb, 2Gb, and 4Gb DDR3 DRAM technologies supported for these devices: o UDIMM DDR3 - SR x8 and x16 data widths, DR - x8 data width o
  • Intel H2000JF | Technical Product Specification - Page 29
    Product Architecture Overview Intel® Server Board S2600JF TPS Table 4. UDIMM Support Guidelines Notes: 1. 2. 3. Ranks Per DIMM and Data Width SRx8 ECC DRx8 ECC Memory Capacity Per DIMM1 1GB 2GB 2GB 4GB 4GB 8GB Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel
  • Intel H2000JF | Technical Product Specification - Page 30
    Intel® Server Board S2600JF TPS Product Architecture Overview Note: Although mixed DIMM configurations are supported, Intel® only performs platform validation on systems that are configured with identical DIMMs installed. Each processor provides four banks of memory, each capable of supporting up
  • Intel H2000JF | Technical Product Specification - Page 31
    Product Architecture Overview Intel® Server Board S2600JF TPS The following are generic DIMM population requirements that generally apply to the Intel® Server Board S2600JF.  All DIMMs must be DDR3 DIMMs.  Unbuffered DIMMs can be ECC only.  Mixing of Registered and Unbuffered DIMMs is not
  • Intel H2000JF | Technical Product Specification - Page 32
    Intel® Server Board S2600JF TPS Product reserve and is not available as system memory. The spare rank must have identical or larger memory capacity than all the other ranks (sparing Processor Intergrated I/O Module (I/O) The processor's integrated I/O module provides features traditionally supported
  • Intel H2000JF | Technical Product Specification - Page 33
    Overview Intel® Server Board S2600JF TPS  Non-Transparent Bridge: PCI Express* Non-Transparent Bridge (NTB) acts as a gateway that enables high performance, low overhead communication between two intelligent subsystems; the local and the remote subsystems. The NTB allows a local processor to
  • Intel H2000JF | Technical Product Specification - Page 34
    Intel® Server Board S2600JF TPS Product Architecture Overview Figure 11.PCI Express* Lane distribution scheme Revision 1.3 21 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 35
    Intel® Server Board S2600JF TPS S2600JF supports off-board standard full height, full length I/O cards including double wide GPU boards. To support GPU boards, each riser will need to provide 66W of 12V power as well as 10W of 3.3V power in the case of 2 x8 boards being hosted in customized chassis
  • Intel H2000JF | Technical Product Specification - Page 36
    , the server board supports the option of adding a single I/O module providing external ports for a variety of networking interfaces. The I/O module attaches to a high density 80-pin connector of I/O module carrier on the Riser 2. Refer to Intel® Server System H2000JF Technical Product Specification
  • Intel H2000JF | Technical Product Specification - Page 37
    Management Functional Overview Intel® Server Board S2600JF TPS SATA SATA 6Gps SAS SAS SAS 3Gps SAS 3Gps Intel® C600-A/B USB 2 USB 2.0 EXT USB 2.0 Type A USB 2.0 2x USB 2.0 INT PCI-E GEN2 x4 (4GB/s) PCI-E GEN1 x1 SMBUS PORTS 2 USB 2.0 (480Mbs) LPC (33MHz) SERVER ENGINES PILOT 3 IBMC
  • Intel H2000JF | Technical Product Specification - Page 38
    Intel® Server Board S2600JF TPS Platform Management Functional Overview independently be configured to support four x1s, two x2s, one x2 and two x1s, or one x4 port widths. From PCH on Intel® Server Board S2600JF, PCIe Port8 x1 Gen2 is connected to BMC Gen1 Uplink. Ports 1-4 are connected to Intel
  • Intel H2000JF | Technical Product Specification - Page 39
    the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for some elements). Intel® Server Board S2600JF implements six SATA/SAS ports. The implementation is as follows: Table 9. Intel® Server Board S2600JF SATA/SAS port Port# 0 1 0 1 SCU0 2 3 Speed 6Gb
  • Intel H2000JF | Technical Product Specification - Page 40
    Intel® Server Board S2600JF TPS Platform Management Functional Overview Additional information for the on-board RAID features and functionality can be found in the Intel® RAID Software Users Guide (Intel® Document Number D29305). 3.4.5 PCI Interface The Intel® C600 PCH PCI Interface provides a 33
  • Intel H2000JF | Technical Product Specification - Page 41
    Functional Overview Intel® Server Board S2600JF TPS restored. This is required to save and restore system state after power has been power states. The PCH contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 4.0a. 3.4.14 Fan Speed Control The Intel
  • Intel H2000JF | Technical Product Specification - Page 42
    Intel® Server Board S2600JF TPS Platform Management Functional Overview 3.4.16 KVM/Serial Over LAN (SOL) Function These functions support memory, or PCI configuration space. Also, no interrupts or power management events are generated from the disabled functions.  Intruder Detect: The Intel
  • Intel H2000JF | Technical Product Specification - Page 43
    Platform Management Functional Overview Intel® Server Board S2600JF TPS 3.4.19 System Management Bus (SMBus 2.0*) The Intel® C600 PCH contains a SMBus* Host interface that allows the processor to communicate with SMBus* slaves. This interface is compatible with most I2C devices. Special I2C
  • Intel H2000JF | Technical Product Specification - Page 44
    address + 4 The Intel® Server Board S2600JF has a white MAC address sticker included with the board. The sticker displays the NIC 1 MAC address in both bar code and alphanumeric formats. 3.4.20.2 LAN Manageability Port 2 of the Intel® i350 NIC will be used by the BMC firmware to send management
  • Intel H2000JF | Technical Product Specification - Page 45
    ® Server Board S2600JF TPS Intel® i350 NIC will have an integrated digital thermal sensor accessible through CSR and manageability registers. The thermal sensor can be programmed to trigger digital pins and thermal throttling with hysteresis. 3.5 InfiniBand* Controller Intel® Server Board S2600JFQ
  • Intel H2000JF | Technical Product Specification - Page 46
    factor Pluggable (QSFP) connector Port of the Mellanox* ConnectX-3* is connected to a single QSFP connector on Intel® Server Board S2600JF (available on SKU: S2600JFQ and S2600JFF). Following is the application reference between Mellanox* ConnectX-3* and QSFP: Figure 17. Connection between ConnectX
  • Intel H2000JF | Technical Product Specification - Page 47
    Overview Intel® Server Board S2600JF TPS 3.6 Integrated Baseboard Management Controller Overview The server board utilizes the Baseboard Management features of the ServerEngines* Pilot-III Server Management Controller. The following is an overview of the features as implemented on the server board
  • Intel H2000JF | Technical Product Specification - Page 48
    Intel® Server Board S2600JF TPS Platform Management Functional Overview The Integrated BMC is provided by an embedded ARM9 controller and associated peripheral functionality that is required for IPMI-based server management. Firmware usage of these hardware features is platform dependent. The
  • Intel H2000JF | Technical Product Specification - Page 49
    Management Functional Overview Intel® Server Board S2600JF TPS  Up to 16 Shared GPIO available for host processor  Programmable Wake-up Event Support  Plug and Play Register Set  Power Supply Control 3.6.1.1 Keyboard and Mouse Support The server board does not support PS/2 interface
  • Intel H2000JF | Technical Product Specification - Page 50
    Intel® Server Board S2600JF TPS Platform Management Functional Overview The BIOS supports dual-video mode when an add-in video card is installed.  In the single mode (dual monitor video = disabled), the on-board video controller is disabled when an add-in video card is detected.  In the dual
  • Intel H2000JF | Technical Product Specification - Page 51
    Firmware External Product Specification (EPS) (Intel® Order Number: G31813) and BIOS Core External Product Specification (EPS) for Intel® Server products based on the Intel® Xeon® processor E5- 4600,2600, and 1600 product families. 4.1 Baseboard Management Controller (BMC) Firmware Feature Support
  • Intel H2000JF | Technical Product Specification - Page 52
    Intel® Server Board S2600JF TPS Platform Management Functional Overview  ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS  BMC self-test: The BMC performs initialization and run-time self-tests and makes results available to external entities See also
  • Intel H2000JF | Technical Product Specification - Page 53
    Overview Intel® Server Board S2600JF TPS button presses. The chassis ID LED is turned on using a front panel button or a command  Power state retention  Power fault analysis  Intel® Light-Guided Diagnostics  Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on
  • Intel H2000JF | Technical Product Specification - Page 54
    Intel® Server Board S2600JF TPS Platform Management Functional Overview  Sensor and Memory Thermal Management  Power Supply Fan Sensors  Enable/Disable of System Reset Due CPU Errors  Energy Star Server Support  SmaRT/CLST  Power Supply Cold Redundancy  Power Supply FW Update  Power Supply
  • Intel H2000JF | Technical Product Specification - Page 55
    Platform Management Functional Overview Intel® Server Board S2600JF TPS 4.2 Advanced Configuration and Power Interface (ACPI) The server board has support for the following ACPI states: Table 15. ACPI Power States State S0 S1 S2 S3 S4 S5 Supported Yes Yes No No No Yes Description Working. 
  • Intel H2000JF | Technical Product Specification - Page 56
    Intel® Server Board S2600JF TPS Platform Management Functional Overview 4.4 BMC Internal Timestamp Clock The BMC maintains an internal timestamp clock that is used by various BMC subsystems, for example, for time stamping SEL entries. As part of BMC initialization after AC power is applied or the
  • Intel H2000JF | Technical Product Specification - Page 57
    Platform Management Functional Overview Intel® Server Board S2600JF TPS Table 16. Standard Channel Assignments Channel ID 0 1 2 3 4 5 6 Primary IPMB Interface LAN 1 LAN 2 LAN3 1 (Provided by the Intel® Dedicated Server Management NIC) Reserved USB Secondary IPMB Supports Sessions No Yes
  • Intel H2000JF | Technical Product Specification - Page 58
    Intel® Server Board S2600JF TPS Platform IPMI spec and includes RMCP and RMCP+ sessions (including all the payloads supported) 2. KVM is a RMCP+ Payload Type. Not an IPMI session. 3. These sessions are not defined by IPMI Specification and are not based on IPMI protocol. Counting them as IPMI
  • Intel H2000JF | Technical Product Specification - Page 59
    Platform Management Functional Overview Intel® Server Board S2600JF TPS Note: The number of possible active session values returned by Get Session Info is the total number of allocated memory session slots in BMC firmware for IPMI Sessions. The actual number of IPMI sessions that can be
  • Intel H2000JF | Technical Product Specification - Page 60
    ) 1000M (10M in DC off state) 1000M 4.6.5 IPV6 Support In addition to IPv4, the Intel® Server Board S2600JF supports IPv6 for manageability channels. Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration Parameters commands as well as through a Web Console IPv6
  • Intel H2000JF | Technical Product Specification - Page 61
    Platform Management Functional Overview Intel® Server Board S2600JF TPS The three possible IPv6 IP Address Sources for configuring the BMC are:  Static (Manual): The IP, Prefix, and Gateway parameters are manually configured by the user. The BMC ignores any Router Advertisement messages received
  • Intel H2000JF | Technical Product Specification - Page 62
    Intel® Server Board S2600JF TPS Platform Management Functional Overview time. Any command that results in an overflow of the SEL beyond the allocated space is rejected with an "Out of Space" IPMI completion code (C4h). 4.7.1 Servicing Events Events can be received while the SEL is being cleared
  • Intel H2000JF | Technical Product Specification - Page 63
    Platform Management Functional Overview Intel® Server Board S2600JF TPS 4.9 Field Replaceable Unit (FRU) Inventory Device The BMC implements the interface for logical FRU inventory devices as specified in the Intelligent Platform Management Interface Specification, Version 2.0. This functionality
  • Intel H2000JF | Technical Product Specification - Page 64
    Features The Intel® Server Board S2600JF product includes support for an upgrade module to support the advanced server management functionality. Table 21. Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection
  • Intel H2000JF | Technical Product Specification - Page 65
    Platform Management Functional Overview Intel® Server Board S2600JF TPS 4.12.1 Enabling Advanced firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is available remotely from the embedded web server as a Java applet. This feature is enabled when the Intel
  • Intel H2000JF | Technical Product Specification - Page 66
    Intel® Server Board S2600JF TPS feature supports multiple encryption firmware update) will require the session to be re-established. KVM sessions persist across system reset, but not across an AC power loss. 4.12.1.6 Timeout The remote KVM session will automatically timeout after a configurable
  • Intel H2000JF | Technical Product Specification - Page 67
    Management Functional Overview Intel® Server Board S2600JF TPS As the server is powered up, the remote KVM session displays the complete BIOS boot process. The user is able interact with BIOS setup, change and save settings as well as enter and interact with option ROM configuration screens. At
  • Intel H2000JF | Technical Product Specification - Page 68
    Intel® Server Board S2600JF TPS and is not user-configurable. Media redirection sessions persist across system reset but not across an AC power loss or BMC reset. interface supports strong security (authentication, encryption, and firewall support) since it enables remote server configuration and
  • Intel H2000JF | Technical Product Specification - Page 69
    Platform Management Functional Overview Intel® Server Board S2600JF TPS web session to be initiated. Encryption using 128-bit SSL is supported. User authentication is based on user id and password. The GUI presented by the embedded web server authenticates the user before allowing a web session to
  • Intel H2000JF | Technical Product Specification - Page 70
    Intel® Server Board S2600JF TPS Platform Management Functional Overview 4.12.5 Local Directory Authentication Protocol (LDAP) The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the Integrated BMC for the purpose of authentication and authorization. The
  • Intel H2000JF | Technical Product Specification - Page 71
    Platform Management Functional Overview Intel® Server Board S2600JF TPS  Static Closed Loop Thermal Throttling (Static-CLTT): CLTT control registers are configured by BIOS MRC during POST. The memory throttling is run as a closed-loop system with the DIMM temperature sensors as the control input.
  • Intel H2000JF | Technical Product Specification - Page 72
    processor P and T state changes for power limiting. PMBus*-compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM. The NM architecture applicable to this generation of servers is defined by the NPTM Architecture Specification
  • Intel H2000JF | Technical Product Specification - Page 73
    Engine (ME) Distributed Model The Intel® Server Board S2600JF covered in this specification will require Node Manager 2.0 (NM2.0) support. The following management architecture would need to be supported on the baseboard to meet product and validation requirements. The NM 2.0 functionality
  • Intel H2000JF | Technical Product Specification - Page 74
    Intel® Server Board S2600JF TPS power supplies for support of various NM-related features. This bus is shared with the BMC, which polls these PMBus* power supplies for sensor monitoring purposes (for example, power supply status, input power BMC participates in ME firmware update.  Integrated BMC
  • Intel H2000JF | Technical Product Specification - Page 75
    Platform Management Functional Overview Intel® Server Board S2600JF TPS  BMC may be queried by the ME for inlet temperature readings 4.14.5 ME Power and Firmware Startup On Intel® Server Board S2600JF, the ME is on standby power. The ME FW will begin its startup sequence at the same time that the
  • Intel H2000JF | Technical Product Specification - Page 76
    PMBus* 1.1 are supported and required to support Intel® Dynamic Power Node Manager. Intel® Server Board S2600JF supports the features of Intel® Dynamic Power Node Manager version 1.5 except the inlet temperature sensor. 4.15.4 Node Power Policies When working with Intel® Server Chassis H2000JF, the
  • Intel H2000JF | Technical Product Specification - Page 77
    Setup Interface Intel® Server Board S2600JF TPS 5. BIOS Setup Interface 5.1 HotKeys Supported During POST Certain "HotKeys" are recognized during POST. A HotKey a key or key combination that is recognized as an unprompted command input, that is, the operator
  • Intel H2000JF | Technical Product Specification - Page 78
    Intel® Server Board S2600JF TPS BIOS Setup Interface 5.3 BIOS Boot Pop-up Menu The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be invoked by pressing the key during POST. The BBS Pop-up menu displays all available
  • Intel H2000JF | Technical Product Specification - Page 79
    BIOS Setup Interface Intel® Server Board S2600JF TPS The Setup page layout is sectioned into functional areas. Each occupies a specific open a new screen with a further group of options for specific functionality. In this case, the operator navigates to the desired selection and presses
  • Intel H2000JF | Technical Product Specification - Page 80
    Intel® Server Board S2600JF TPS BIOS Setup Interface To enter the BIOS Setup using a keyboard (or emulated keyboard), press the function key during boot time when the OEM or Intel for informative purposes. Each value field contains configurable parameters. Depending on the security option
  • Intel H2000JF | Technical Product Specification - Page 81
    BIOS Setup Interface Intel® Server Board S2600JF TPS Key + Option Change Value Setup affecting any existing field values. Pressing the key causes the following message to display: Save configuration and reset? Yes No If "Yes" is highlighted and is pressed, all changes are
  • Intel H2000JF | Technical Product Specification - Page 82
    Intel® Server Board S2600JF TPS BIOS Setup Interface  The Help Text entry is the vary, depending on the option(s) installed. For example, is replaced by the actual value for "Total Memory".  Information enclosed in square brackets ([ ]) in the tables identifies
  • Intel H2000JF | Technical Product Specification - Page 83
    BIOS Setup Interface Intel® Server Board S2600JF TPS Table 27. Screen Map Categories (Top Tabs) Main Screen (Tab) Advanced Screen (Tab      Security Screen (Tab) Server Management Screen (Tab Boot Options Screen (Tab Boot Manager Screen (Tab) Error Manager Screen (Tab) Exit Screen (Tab)
  • Intel H2000JF | Technical Product Specification - Page 84
    Intel® Server Board S2600JF TPS BIOS Setup Interface Main Advanced Security Server Management Boot Options Boot Manager Logged in as: Platform ID System BIOS BIOS Version Build Date Memory Total Memory Quiet Boot POST Error Pause System Date System Time Administrator/User
  • Intel H2000JF | Technical Product Specification - Page 85
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item Total Memory Quiet Boot POST Error Pause System Date System Time Options Enabled Disabled Help Text Comments Information only. Displays the total physical memory installed in the system, in MB or GB. The term physical memory
  • Intel H2000JF | Technical Product Specification - Page 86
    Intel® Server Board S2600JF TPS BIOS Setup Interface Main Advanced Security Server Management Boot Options Boot Manager ► Processor ► Power & Performance ► Memory Configuration ► Mass Storage Controller Configuration ► PCI Configuration ► Serial Port Configuration ► USB Configuration ► System
  • Intel H2000JF | Technical Product Specification - Page 87
    BIOS Setup Interface Intel® Server Board S2600JF TPS Advanced Processor Configuration Processor ID Processor Frequency Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor ID Processor 1 Version Processor 2 Version Current Intel® QPI Link Speed Intel® QPI Link Frequency Intel® QPI
  • Intel H2000JF | Technical Product Specification - Page 88
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Microcode Revision Options L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor Version Processor 1 Version Processor 2 Version Current QPI Link Speed QPI Link Frequency Current QPI Frequency Select Auto Max 6.4 GT/s 7.2 GT/s
  • Intel H2000JF | Technical Product Specification - Page 89
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item Processor C3 Options Enabled Disabled Processor C6 Enabled Disabled Intel® Hyper-Threading Technology Enabled Disabled Active Processor Cores Execute Disable Bit All 1 2 3 4 5 6 7 Enabled Disabled Intel® Virtualization
  • Intel H2000JF | Technical Product Specification - Page 90
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item MLC Streamer Options Enabled Disabled MLC Spatial Prefetcher Enabled Disabled DCU Data Prefetcher Enabled Disabled DCU Instruction from L2 or system memory during unused cycles if it sees that the processor core has accessed
  • Intel H2000JF | Technical Product Specification - Page 91
    BIOS Setup Interface Intel® Server Board S2600JF TPS Advanced Power & Performance Power and Performance Policy Performance / Balanced Performance / Balanced Power / Power [Performance] Optimization is strongly toward performance, even at the expense of energy efficiency. [Balanced Performance]
  • Intel H2000JF | Technical Product Specification - Page 92
    Intel® Server Board S2600JF TPS BIOS Setup Interface BIOS Features Available Settings Performance Balanced Balanced Power Enhanced Intel® SpeedStep® Enabled/Disabled (Enabled) Performance Power (Enabled) (Enabled) (Enabled) Technology Processor C3 Enabled/Disabled (Disabled) (
  • Intel H2000JF | Technical Product Specification - Page 93
    Intel® Server Board S2600JF TPS BIOS Features ENERGY_PERF _BIAS mode Available Settings Performance Performance/Bala nced Performance/Bala nced Power/Power Performance Balanced Performance (Balanced Performance) Balanced Power Balanced Power Power Power 5.4.2.6 Memory Configuration
  • Intel H2000JF | Technical Product Specification - Page 94
    Intel® Server Board S2600JF TPS BIOS Setup Interface Table 33. Setup Utility - Memory Configuration Screen Fields Setup Item Total Memory Effective Memory Current Configuration Options Comments Information only. The amount of memory available in the system in the form of installed DDR3 DIMMs in
  • Intel H2000JF | Technical Product Specification - Page 95
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item DIMM_ XY Options Comments Displays the state of each DIMM socket present on the board. Each DIMM socket field reflects one of the following possible states: Operational - There is a DDR3 DIMM installed and operational in this slot.
  • Intel H2000JF | Technical Product Specification - Page 96
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Memory Rank Sparing Yes Possible No Options Memory Lockstep Yes Possible No Select Memory RAS Configuration Maximum Performance Mirroring Lockstep NUMA Optimized Enabled Disabled Help Text Allows the user to select the
  • Intel H2000JF | Technical Product Specification - Page 97
    BIOS Setup Interface Intel® Server Board S2600JF TPS Advanced Mass Storage Controller Configuration AHCI Controller Configuration SATA/SAS Controller Configuration AHCI Capable SATA Controller SAS/SATA Capable Controller 2 ports of 6Gb/s SATA 4 ports in SAS mode Disable/Compatibility/Enhanced/
  • Intel H2000JF | Technical Product Specification - Page 98
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item SATA Port x Options Not the Advanced screen, then select the desired screen. Advanced PCI Configuration Maximize Memory below 4GB Memory Mapped I/O Size Memory Mapped I/O above 4GB Onboard Video Legacy VGA Socket Dual Monitor Video
  • Intel H2000JF | Technical Product Specification - Page 99
    Intel® Server Board S2600JF TPS Table 36. Setup Utility - PCI Configuration Screen Fields Setup Item Maximize Memory below 4GB Memory Mapped I/O Size Memory Mapped I/O above 4GB Onboard Video Legacy VGA Socket Options Enabled Disabled Help Text BIOS maximizes memory attached to Processor Socket 1
  • Intel H2000JF | Technical Product Specification - Page 100
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Dual Monitor Video NTB PCIe Port on CPU Socket 1 Enable NTB Bars Crosslink Control Override NTB PCIe Port on CPU Socket 2 Enable NTB Bars Crosslink Control Override NIC Configuration Options Enabled Disabled Help Text If enabled.
  • Intel H2000JF | Technical Product Specification - Page 101
    IOM1 Port3 MAC Address IOM1 Port4 MAC Address IO Module 1 Type IOM1 InfiniBand Option ROM IOM1 Port1 GUID IOM1 Port1 MAC Address Intel® Server Board S2600JF TPS Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled
  • Intel H2000JF | Technical Product Specification - Page 102
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item PXE 1GbE Option ROM Options Enabled Disabled iSCSI 1GbE/10GbE Option ROM Enabled Disabled Onboard NIC1 Type Onboard NIC2 Type IO
  • Intel H2000JF | Technical Product Specification - Page 103
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item NIC1 Controller NIC2 Controller NIC2 InfiniBand* Option ROM IOM1 InfiniBand* Option ROM NIC2 Port1 GUID IOM1 Port1 GUID NIC1 Port1 NIC1 Port2 NIC2 Port1 NIC2 Port2 NIC1 Port1 PXE NIC1 Port2 PXE NIC2 Port1 PXE NIC2 Port2 PXE IOM1 Port1
  • Intel H2000JF | Technical Product Specification - Page 104
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item NIC1 Port1 MAC Address NIC1 Port2 Comments 12 hex digits of the MAC address. 5.4.2.11 Serial Port Configuration The Serial Port Configuration screen allows the user to configure the Serial A [COM 1] and Serial B [COM2] ports. To
  • Intel H2000JF | Technical Product Specification - Page 105
    BIOS Setup Interface Intel® Server Board S2600JF TPS 5.4.2.12 USB Configuration The USB Configuration screen allows the user to configure the USB controller options. To access this screen from the Main screen, select Advanced > USB Configuration. To move to another screen, press the key
  • Intel H2000JF | Technical Product Specification - Page 106
    Intel® Server Board S2600JF TPS BIOS I/O port 60h / 64h emulation support. Note: This may be needed for legacy USB keyboard support when using an OS that is select the desired screen. Advanced System Acoustic and Performance Configuration Set Throttling Mode Altitude Set Fan Profile Fan PWM Offset
  • Intel H2000JF | Technical Product Specification - Page 107
    BIOS Setup Interface Intel® Server Board S2600JF TPS Table 40. Setup Utility - System Acoustic and Performance Configuration Screen board in an Intel® chassis with inlet and outlet air temperature sensors and TSOD. The firmware can update the offset registers for closed loop during runtime, as BIOS
  • Intel H2000JF | Technical Product Specification - Page 108
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Set Fan Profile Options Performance Acoustics Fan PWM 0 Offset Quiet Fan Idle Disabled Mode Enabled Help Text [Performance] - Fan control provides primary system cooling before attempting to throttle memory configuration
  • Intel H2000JF | Technical Product Specification - Page 109
    BIOS Setup Interface Intel® Server Board S2600JF TPS Main Advanced Security Server Management Boot Options Boot Manager Administrator Password Status User Password Set Administrator Password Set User Password Power ON Password Front Panel Lockout
  • Intel H2000JF | Technical Product Specification - Page 110
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Power ON Password Options Enabled Disabled Front Panel Lockout Enabled Disabled Help Text Enable Power On Password support. If enabled, password entry is required in order to boot the system Comments When Power On Password
  • Intel H2000JF | Technical Product Specification - Page 111
    BIOS Setup Interface Intel® Server Board S2600JF TPS Main Advance d Security Server Management Boot Options Boot Manager Assert NMI on SERR Assert NMI on PERR Enabled / Disabled Enabled / Disabled Reset on CATERR Reset on ERR2 Enabled / Disabled Enabled / Disabled Resume on AC Power Loss
  • Intel H2000JF | Technical Product Specification - Page 112
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item Reset on CATERR Options Enabled Disabled Reset on ERR2 Enabled Disabled Resume on AC Power Loss Stay Off Last state Reset Clear System Event Enabled Log Disabled FRB-2 Enable Enabled Disabled O/S Boot Watchdog Enabled
  • Intel H2000JF | Technical Product Specification - Page 113
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item Shutdown Policy Options Enabled Disabled Console Redirection System Information BMC LAN Configuration Help Text Enable/Disable Shutdown Policy View/Configure console redirection information and settings. View system information
  • Intel H2000JF | Technical Product Specification - Page 114
    Intel® Server Board S2600JF TPS BIOS terminal application. [None] - Configure for no flow control. [RTS/CTS] - Configure for hardware flow control. Serial numbers, and firmware revisions. This is an Information Only screen To access this screen from the Main screen, select Server Management >
  • Intel H2000JF | Technical Product Specification - Page 115
    BIOS Setup Interface System Information Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision SDR Revision UUID Intel® Server Board S2600JF TPS Server
  • Intel H2000JF | Technical Product Specification - Page 116
    Intel® Server Board S2600JF TPS BIOS Setup Interface 5.4.2.18 BMC LAN Configuration The BMC configuration screen allows the Setup user to configure the BMC Baseboard LAN channel and the RMM4 LAN channel, and to manage BMC User settings for up to five BMC Users. To access this
  • Intel H2000JF | Technical Product Specification - Page 117
    BIOS Setup Interface Intel® Server Board S2600JF TPS BMC LAN Configuration Server Management Baseboard LAN configuration IP Source IP Address Subnet Mask Gateway IP Baseboard LAN IPV6 configuration IPV6 IPV6 source IPV6 address Gateway IPV6 IPV6 Prefix Length Static/Dynamic [0.0.0.0 IP display/
  • Intel H2000JF | Technical Product Specification - Page 118
    Intel® Server Board S2600JF TPS BIOS Setup Interface Setup Item IP source Options Static Dynamic IP address Subnet Mask Gateway IP Intel Enter> to edit. Select the user id to configure. Available only when IP source for any one length is 15 characters and case sensitive. Note: Password entered
  • Intel H2000JF | Technical Product Specification - Page 119
    BIOS Setup Interface Intel® Server Board S2600JF TPS 5.4.2.19 Boot Options Screen (Tab) The Boot Options screen displays all bootable media encountered during POST, and allows the user to configure the desired order in which boot devices are to be tried. The first boot device in the specified
  • Intel H2000JF | Technical Product Specification - Page 120
    Intel® Server Board S2600JF TPS BIOS Setup Interface Table 46. Setup Utility - Boot Options Screen it is restored on the next system reboot. It cannot be permanently deleted. If enabled, the BIOS only loads modules required for booting EFI-aware Operating Systems. Grayed out when [SW RAID] SATA
  • Intel H2000JF | Technical Product Specification - Page 121
    BIOS Setup Interface Intel® Server Board S2600JF TPS Setup Item Options Reset Static Boot Order Yes This screen is only available when there is at least one hard disk device available in the system configuration. Note that a USB attached Hard Disk drive or a USB Key device formatted as a hard
  • Intel H2000JF | Technical Product Specification - Page 122
    Intel® Server Board S2600JF TPS BIOS Setup Interface To access this screen from the Main screen, select Boot Options > Network Device Order. To move to Shell Boot Manager Screen (Tab) Help Text Remove an EFI boot option from the boot order. Revision 1.3 109 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 123
    BIOS Setup Interface Intel® Server Board S2600JF TPS The Boot Manager screen allows the user to view a list of : This list is not the system boot option order. Use the Boot Options menu to view and configure the system boot option order. Select this option to boot now. Note: This list is not the
  • Intel H2000JF | Technical Product Specification - Page 124
    Intel® Server Board S2600JF TPS Error Manager Save&Exit ► View Event Log ERROR CODE SEVERITY 5224 Major BIOS whether to save or discard the configuration changes made on other Setup screens. It also allows the user to restore the BIOS settings to the factory defaults
  • Intel H2000JF | Technical Product Specification - Page 125
    Setup Interface Intel® Server Board S2600JF TPS Table 52. Setup Utility - Exit Screen Fields Setup Item Save Changes and Exit Discard Changes and Exit Save Changes Discard Changes Load Default Values Save as User Default Values Load User Default Values Help Text Exit the BIOS Setup utility after
  • Intel H2000JF | Technical Product Specification - Page 126
    Intel® Server Board S2600JF TPS Configuration Jumpers 6. Configuration Jumpers The following table provides a summary and description of configuration, test, and debug jumpers on the Intel® Server Board S2600JF. The server board has several 3-pin jumper blocks that can be used. Pin 1 on each
  • Intel H2000JF | Technical Product Specification - Page 127
    Configuration Jumpers Intel® Server Board S2600JF TPS Table 53. Server Board Jumpers (J6B1, J1E2, J1E3, J1E1, J1D5) Jumper Name J6B1: BMC Force Update jumper J1E2: ME Force Update J1E3: Password Clear J1E1: BIOS Recovery Mode J1D5: BIOS Default Jumper Position 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2
  • Intel H2000JF | Technical Product Specification - Page 128
    Intel® Server Board S2600JF TPS Configuration Jumpers 11. Reconnect the AC cord and power up the server. Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the enabled position. You should never run the server with the BMC Force Update jumper set in this position
  • Intel H2000JF | Technical Product Specification - Page 129
    Configuration Jumpers Intel® Server Board S2600JF TPS Table 56. Password Clear Jumper Jumper Position 1-2 Mode of Operation Note Normal Normal mode, password in protection 2-3 Clear Password BIOS password is cleared Steps to clear the BIOS password: 1. Power down server. Do not unplug the
  • Intel H2000JF | Technical Product Specification - Page 130
    Intel® Server Board S2600JF TPS Configuration Jumpers After the update is complete, a message displays, stating the "BIOS has been updated to clear BIOS settings: 1. Power down server. Do not unplug the power cord. 2. Open the server chassis. For instructions, see your server chassis documentation.
  • Intel H2000JF | Technical Product Specification - Page 131
    Configuration Jumpers Intel® Server Board S2600JF TPS Note: Removing AC Power before performing the BIOS settings Clear operation causes the system to automatically power up and immediately power down, after the procedure is followed and AC power is re-applied. If this happens, remove the AC power
  • Intel H2000JF | Technical Product Specification - Page 132
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out 7. Connector/Header Locations and Pin-out 7.1 Power Connectors To facilitate customers who want to cable to this board from a power supply, the power connector is implemented through two 6pin pin Minifit Jr* connectors, that
  • Intel H2000JF | Technical Product Specification - Page 133
    out Intel® Server Board S2600JF TPS Table 62. Bridge Board BIOS and the Integrated BMC support provide the functionality of the various supported control panel buttons and LEDs. The following sections describe the supported functionality of each control panel feature. 120 Revision 1.3 Intel
  • Intel H2000JF | Technical Product Specification - Page 134
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out 7.3.1 Power Button The BIOS supports a front control panel power button. Pressing the power button initiates a request that the Integrated BMC forwards to the ACPI power state machines in the chipset. It is monitored by the
  • Intel H2000JF | Technical Product Specification - Page 135
    Connector/Header Locations and Pin-out State S1 Sleep S0 Intel® Server Board S2600JF TPS ACPI Yes Yes Power LED ~1 Hz blink Solid on 7.3.5 System Status LED Note: The system status LED state shows the state for the current, most severe fault. For example,
  • Intel H2000JF | Technical Product Specification - Page 136
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out Color Green Green State Solid on ~1 Hz blink System Status Ok Degraded Amber ~1 Hz blink Non-Fatal Amber Solid on Fatal Off NA Not ready Description System ready BIOS detected  Unable to use all of the installed
  • Intel H2000JF | Technical Product Specification - Page 137
    -out Intel® Server Board S2600JF TPS 7.3.6 Chassis ID LED The chassis ID LED provides a visual indication of a system being serviced. The state of the chassis ID LED is affected by the following:  Toggled by the chassis ID button  Controlled by the Chassis Identify command (IPMI)  Controlled
  • Intel H2000JF | Technical Product Specification - Page 138
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out Pin Pin Name Description B12 Spare B13 Spare B14 GND B15 SMBUS_R4 CLK 4- Rx Lane 5+ Rx Lane 5- Rx Lane 6+ Rx Lane 6- Rx Lane 7+ Rx Lane 7- Rx Lane 8+ Rx Lane 8- Rx Lane 9+ Revision 1.3 125 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 139
    Connector/Header Locations and Pin-out Intel® Server Board S2600JF TPS Pin Pin Name B57 GND B58 PETxP10 B59 PETxN10 B60 GND B61 GND B62 PETxP11 B63 PETxN11 receive data RGMII receive data RGMII receive data RGMII receive Cntrl RGMII receive Clock 126 Revision 1.3 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 140
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out Pin Pin Name B16 PERST# B17 WAKE# B18 PETxP0 B19 PETxN0 B20 GND B21 GND 6+ Rx Lane 6- Rx Lane 7+ Rx Lane 7- Rx Lane 8+ Rx Lane 8- Rx Lane 9+ Rx Lane 9- Rx Lane 10+ Rx Lane 10- Revision 1.3 127 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 141
    Connector/Header Locations and Pin-out Intel® Server Board S2600JF TPS Pin Pin Name B63 PETxN11 B64 GND B65 GND B66 PETxP12 B67 PETxN12 B68 GND B69 GND B70 PETxP13 66W for GPU For wake on LAN Clock pair 1 Clock pair 1 Rx Lane 0+ Rx Lane 0Rx Lane 1+ 128 Revision 1.3 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 142
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out Pin Pin Name B23 GND B24 PETxP1 B25 PETxN1 B26 GND B27 GND B28 PETxP2 B29 PETxN2 Rx Lane 9+ Rx Lane 9- Rx Lane 10+ Rx Lane 10- Rx Lane 11+ Rx Lane 11- Rx Lane 12+ Rx Lane 12- Revision 1.3 129 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 143
    /Header Locations and Pin-out Intel® Server Board S2600JF TPS Pin Pin Name B70 GND 2x8 CPU1 Riser ID (0) Riser ID (1) 1 0 1 0* CPU2 Riser ID (2) 1 0 Notes: 1. 2. S2600JF board supports only one GPIO for slot 2 riser ID. However, there are three types of riser defined for Slot 2. o PCIe
  • Intel H2000JF | Technical Product Specification - Page 144
    Intel® Server Board S2600JF TPS Connector/ server board provides one SATA port connector named SATA-1 port (J6D1) on board. Additional four SAS ports are provided through bridge board. The pin configuration for each connector is identical and defined in the following table. Revision 1.3 131 Intel
  • Intel H2000JF | Technical Product Specification - Page 145
    and Pin-out Intel® Server Board S2600JF TPS Table 73. configuration of connector is identical and defined in the following table. Table 75. Storage Upgrade Key Connector (J6C4) Pin 1 2 3 4 Signal Description GND DYN_SKU_KEY GND SAS_SATA_RAID_KEY 7.4.7 Serial Port Connectors The server board
  • Intel H2000JF | Technical Product Specification - Page 146
    Intel® Server Board S2600JF TPS Connector/Header Locations and Pin-out 7.4.8 USB Connectors The following table details the pin-out of the external stack USB port 0/1 connectors (J3A1) found on the back edge of the server board. Table 77. External USB port Connector (J3A1) Pin 1 2 3 4 Signal
  • Intel H2000JF | Technical Product Specification - Page 147
    Connector/Header Locations and Pin-out Intel® Server Board S2600JF TPS 7.5 Fan Headers To facilitate the connection of 3 x40mm double rotor fans, a 14 pin header is provided, all fans will share a PWM. Both rotor tachs can
  • Intel H2000JF | Technical Product Specification - Page 148
    Server Board S2600JF has several onboard diagnostic LEDs to assist in troubleshooting board-level issues. This section provides a description the location and function of each LED on the server board. 8.1 Front Panel Support The Intel® Server Board S2600JF supports Mini-FP on Intel® Server Chassis
  • Intel H2000JF | Technical Product Specification - Page 149
    processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the given POST code to the POST code diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a system hang during the POST process
  • Intel H2000JF | Technical Product Specification - Page 150
    product airflow specification -40º C to 70º C (-40º F to 158º F) ± 5% of all nominal voltages Trapezoidal, 35g, 170 inches/sec 36 inches 30 inches 24 inches 18 inches 12 inches 9 inches 5 Hz to 500 Hz 3.13 g RMS random Intel Corporation server boards contain a number of high-density VLSI and power
  • Intel H2000JF | Technical Product Specification - Page 151
    Intel® Server Board S2600JF TPS 9.1.1 Set Throttling Mode This option is used to select the desired memory thermal throttling mechanism. Available settings include: [Auto], [DCLTT], [SCLTT] and [SOLTT]. [Auto] - Factory Default Setting - BIOS power option is reserved for manual adjustment to the
  • Intel H2000JF | Technical Product Specification - Page 152
    Intel® Server Board S2600JF TPS Environmental Limits Specification 9.1.6 Thermal Sensor Input for Fan Speed Control The BMC uses various IPMI sensors as inputs to fan speed control. Some of the sensors are actual physical sensors and some are "virtual" sensors derived from calculations. The
  • Intel H2000JF | Technical Product Specification - Page 153
    ® Server Board S2600JF TPS Figure 15. Fan Control Model 9.2 Processor Thermal Design Power (TDP) Support To allow optimal operation and long-term reliability of Intel® processor-based systems, the processor must remain within the defined minimum and maximum case temperature (TCASE) specifications
  • Intel H2000JF | Technical Product Specification - Page 154
    Intel® Server Board S2600JF TPS Power Supply Specification Guidelines 10. Power Supply Specification Guidelines This section provides power supply specification guidelines recommended for providing the specified server platform with stable operating power requirements. Note: The power supply
  • Intel H2000JF | Technical Product Specification - Page 155
    Power Supply Specification Guidelines Intel® Server Board S2600JF TPS Table 87. Voltage Regulation Limits Parameter +12V +5V stby Tolerance - 5%/+5% returns to chassis shall not exceed 1.0 m. This path may be used to carry DC current. 10.2.7 Closed loop stability The power supply shall be
  • Intel H2000JF | Technical Product Specification - Page 156
    Intel® Server Board S2600JF TPS Power Supply Specification Guidelines any individual or all outputs simultaneously. It also should not trip the protection circuits during turn on. The residual voltage at the power supply outputs for no load condition shall not exceed 100mV when AC voltage is
  • Intel H2000JF | Technical Product Specification - Page 157
    Power Supply Specification Guidelines Intel® Server Board S2600JF TPS requirements for the power supply being turned on and off through the AC input, with PSON held low and the PSON signal, 5 500 Units ms ms ms ms ms ms ms ms ms ms 1000 ms ms 144 Revision 1.3 Intel order number G31608-004
  • Intel H2000JF | Technical Product Specification - Page 158
    Intel® Server Board S2600JF TPS AC Input Vout TAC_on_delay Tsb_on_delay PWOK Tpwok_on Tpwok_holdup Power Supply Specification Guidelines Tvout_holdup Tpwok_off Tpwok_low Tsb_on_delay Tpwok_on Tpwok_off Tpson_pwok 12Vsb PSON Tsb_vout T5Vsb_holdup Tpson_on_delay AC turn on/off cycle PSON
  • Intel H2000JF | Technical Product Specification - Page 159
    or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5V standby is still present even though the server board is powered off.  This server board supports The Intel® Xeon® Processor E5-2600 product family with a Thermal Design Power (TDP) of up
  • Intel H2000JF | Technical Product Specification - Page 160
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Appendix B: Integrated BMC Sensor Tables This appendix lists the sensor identification numbers and information about the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description
  • Intel H2000JF | Technical Product Specification - Page 161
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS A: Auto-rearm M: Manual rearm I: Rearm by init agent on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present. 148 Revision 1.3 Intel order number
  • Intel H2000JF | Technical Product Specification - Page 162
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Table 92. BMC Sensor Table Full Sensor Name (Sensor name in SDR) Power Unit Status (Pwr Unit Status) Sensor # Platform Applicabilit y Sensor Type Event/ Reading Type 01h All Power Unit Sensor Specific 09h 6Fh
  • Intel H2000JF | Technical Product Specification - Page 163
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) IPMI Watchdog (IPMI Watchdog) Physical Security (Physical Scrty) FP Interrupt (FP NMI Diag Int) SMI Timeout (SMI Timeout) System Event Log (System Event Log) System Event (System Event)
  • Intel H2000JF | Technical Product Specification - Page 164
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) (Fan Redundancy) SSB Thermal Trip (SSB Therm Trip) IO Module Presence (IO Mod Presence) SAS Module Presence (SAS Mod Presence) BMC Firmware Health (BMC FW Health) System Airflow (System
  • Intel H2000JF | Technical Product Specification - Page 165
    Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) FW Update Status Sensor # 0x12 R, T c = Non-fatal De Baseboard Temperature 3 24h (Platform Specific) Platformspecific Temperature 01h Threshold 01h [u,l] [c,nc] nc = As Degraded
  • Intel H2000JF | Technical Product Specification - Page 166
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) ) Fan Tachometer Sensors (Chassis specific sensor names) 2Fh 30h-3Fh Platformspecific Chassis and Platform Specific All Chassis and Platform Specific Temperature 01h Temperature 01h
  • Intel H2000JF | Technical Product Specification - Page 167
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) Fan Present Sensors (Fan x Present) Sensor # Platform Applicabilit y Sensor Type Chassis and 40h-4Fh Platform Fan Specific 04h Event/ Reading Type Event Offset Triggers Contrib
  • Intel H2000JF | Technical Product Specification - Page 168
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Power Supply 1 Temperature (PS1 Temperature) Power Supply 2 Temperature (PS2 Temperature) Sensor # Platform Applicabilit y Sensor Type Event/ Reading Type Event Offset Triggers 5Ch
  • Intel H2000JF | Technical Product Specification - Page 169
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) Sensor # Processor 2 Thermal Control % 79h (P2 Therm Ctrl %) Processor 1 ERR2 Timeout 7Ch (P1 ERR2) Processor 2 ERR2 Timeout 7Dh (P2 ERR2) Catastrophic Error 80h (CATERR)
  • Intel H2000JF | Technical Product Specification - Page 170
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # Processor 1 Memory VRD Hot 0-1 94h (P1 Mem01 VRD Hot) Processor 1 Memory VRD Hot 2-3 95h (P1 Mem23 VRD Hot) Processor 2 Memory VRD Hot 0-1 96h (P2 Mem01 VRD Hot)
  • Intel H2000JF | Technical Product Specification - Page 171
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) Sensor # Processor 2 DIMM Aggregate Thermal Margin 2 (P2 DIMM Thrm Mrgn2) Processor 1 DIMM Thermal Trip (P1 Mem Thrm Trip) Processor 2 DIMM Thermal Trip (P2 Mem Thrm Trip) Global
  • Intel H2000JF | Technical Product Specification - Page 172
    Intel® Server Board S2600JF TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name AUX) D4h All Baseboard +1.05V Processor 1 Vccp D6h All (BB +1.05Vccp P1) Baseboard +1.05V Processor 1 Vccp D7h All (BB +1.05Vccp P2) Baseboard +1.5V P1 Memory AB VDDQ D8h All (BB
  • Intel H2000JF | Technical Product Specification - Page 173
    Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600JF TPS Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicabilit y Sensor Type Baseboard +1.1V Standby (BB +1.1V STBY) Baseboard CMOS Battery (BB +3.3V Vbat) Baseboard +1.35V P1 Low Voltage Memory AB VDDQ (BB +1.35
  • Intel H2000JF | Technical Product Specification - Page 174
    Intel® Server Board S2600JF TPS support redundancy (for instance, fan or power supply). 2. This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system state is driven by the fan redundancy sensor. Revision 1.3 161 Intel
  • Intel H2000JF | Technical Product Specification - Page 175
    Sensors and SEL Data Intel® Server Board S2600JF TPS Appendix C: BIOS Sensors and SEL Data BIOS owns a set of IPMI-compliant Sensors. These are actually divided in ownership between BIOS POST (GID = 01) and BIOS SMI Handler (GID = 33). The SMI Handler Sensors are typically for logging runtime
  • Intel H2000JF | Technical Product Specification - Page 176
    Intel® Server Board S2600JF TPS Appendix C: BIOS Sensors and SEL Data Sensor Name Memory RAS Configuration Status Memory ECC Error Legacy PCI Error Sensor Number 02h Sensor Owner (GID) 01h (BIOS POST) Sensor Type 0Ch (Memory) 02h 33h (SMI Handler) 0Ch (Memory) 03h 33h (SMI Handler) 13h (
  • Intel H2000JF | Technical Product Specification - Page 177
    Intel® Server Board S2600JF TPS Sensor Name PCIe Fatal Error (Standard AER Errors) (see Sensor 14h for continuation) PCIe Correctable Error (Standard AER Errors) BIOS Internal 8h = Header Log Overflow 6Fh (Sensor Specific Offset) 0h = System Firmware Error (POST Error Code) 72h (OEM Discrete)
  • Intel H2000JF | Technical Product Specification - Page 178
    Intel® Server Board S2600JF TPS Appendix C: BIOS Sensors and SEL Data Sensor Name (see Sensor 17h for continuation) Chipset Proprietary (reserved for Validation) QPI Link Width Reduced Memory Error Extension (reserved for Validation) Sensor Number Sensor Owner (GID) Handler) Sensor Type
  • Intel H2000JF | Technical Product Specification - Page 179
    Sensors and SEL Data Intel® Server Board S2600JF TPS Sensor Name Sparing Redundancy State Sensor Number 11h Sensor Owner (GID) 33h (SMI Handler) Sensor Type 0Ch (Memory) Memory RAS Mode Select 12h 01h (BIOS POST) 0Ch (Memory) Event/Reading Type Offset Values 0Bh (Discrete, Redundancy State
  • Intel H2000JF | Technical Product Specification - Page 180
    Intel® Server Board S2600JF TPS Appendix C: BIOS Sensors and SEL Data Sensor Name Memory Parity Error Sensor Number 13h Sensor Owner (GID) 33h (SMI Handler) Sensor Type 0Ch (Memory Values 6Fh (Sensor Specific Offset) 2h = Address Parity Error 76h (OEM Discrete) 0h = Atomic Egress Blocked 1h =
  • Intel H2000JF | Technical Product Specification - Page 181
    Appendix C: BIOS Sensors and SEL Data Intel® Server Board S2600JF TPS Sensor Name QPI Fatal Error (continuation address or memory 5h = IIO Write Cache Coherency Violation 6Fh (Sensor Specific Offset) Event Data 2 Event Data 3 ED2 = [7:0] = Node ID 0-3 = CPU1-4 ED3 = No Data 83h 01h (BIOS POST)
  • Intel H2000JF | Technical Product Specification - Page 182
    Intel® Server Board S2600JF TPS Appendix D: POST Code LED Decoder Appendix D: POST Code LED Decoder During the system boot process, the BIOS executes several platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the
  • Intel H2000JF | Technical Product Specification - Page 183
    Code LED Decoder Intel® Server Board S2600JF TPS Table 94. POST Processor 0x15h 0 0 0 1 0 1 0 1 Switch an AP processor to become the new Boot Strap Processor Chipset 0x21h 0 0 1 0 0 0 0 1 Initializing a chipset component Memory 0x22h 0 0 1 0 0 0 1 0 Reading configuration data from memory
  • Intel H2000JF | Technical Product Specification - Page 184
    Intel® Server Board S2600JF TPS Memory Controller 0xBDh 1 0 1 1 1 1 0 1 Memory Initialization of Integrated Memory Controller 0xBEh 1 0 1 1 1 1 1 0 Memory Initialization of Integrated Memory Controller 0xBFh 1 0 1 1 1 1 1 1 Memory Initialization of Integrated Memory SMART if supported by ATA
  • Intel H2000JF | Technical Product Specification - Page 185
    Appendix D: POST Code LED Decoder Intel® Server Board S2600JF TPS Diagnostic LED Decoder 1 = On, 0=Off Checkpoint Upper Nibble MSB Lower Nibble hard drive detection, and so forth) 0xB3h 1 0 1 1 0 0 1 1 Enabling/configuring a fixed media device 0xB4h 1 0 1 1 0 1 0 0 Reserved for fixed media
  • Intel H2000JF | Technical Product Specification - Page 186
    Intel® Server Board S2600JF TPS (PEIM) 0xE2h 1 1 1 0 0 0 1 0 Initial memory found, configured, and installed correctly 0xE3h 1 1 1 0 0 0 1 1 Entering BIOS setup 0xEAh 1 1 1 0 1 1 0 0 Flash Update 0xEBh 1 1 1 0 1 1 0 1 Legacy Option ROM initialization 0xECh 1 1 1 0 1 0 0 0 DXE Drivers
  • Intel H2000JF | Technical Product Specification - Page 187
    Appendix E: Video POST Code Errors Intel® Server Board S2600JF TPS Appendix E: Video POST Code Errors Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,
  • Intel H2000JF | Technical Product Specification - Page 188
    Intel® Server Board S2600JF TPS Appendix E: Video POST Code Errors Error Code 8160 8161 8180 8190 controller in update mode Sensor data record empty System event log full Memory component could not be configured in the selected RAS mode. DIMM Population Error. CLTT Configuration Failure Error.
  • Intel H2000JF | Technical Product Specification - Page 189
    Code Errors Intel® Server Board S2600JF TPS Error Code non-critical variables complete. Unspecified processor component has encountered a nonspecific error services driver component encountered an illegal software state error. DXE boot services driver component encountered an invalid configuration
  • Intel H2000JF | Technical Product Specification - Page 190
    Intel® Server Board S2600JF TPS Appendix E: Video POST Code Errors Error Code 96E7 0xA000 0xA001 0xA002 0xA003 0xA022 0xA027 0xA028 0xA421 0xA500 0xA501 0xA5A0 0xA5A1 0xA5A4 0xA6A0 0xB6A3 Error Message SMM driver component encountered an illegal software state error. TPM device not detected. TPM
  • Intel H2000JF | Technical Product Specification - Page 191
    of memory, which normally resides on the server board. Data Center Management Interface Dynamic Host Configuration Protocal Direct Platform Control Electrically Erasable Programmable Read-Only Memory Enhanced Host Controller Interface Emergency Management Port External Product Specification Fully
  • Intel H2000JF | Technical Product Specification - Page 192
    Intel® Server Board S2600JF TPS Glossary Term Hz I2C IA IBF ICH IC MB IFB ILM IMC INTR IP IPMB IPMI IR ITP KB KCS LAN LCD LED LPC LUN MAC MB ME MD2 MD5 ms MTTR Mux NIC NMI OBF OEM Ohm PECI PEF PEP
  • Intel H2000JF | Technical Product Specification - Page 193
    Glossary Intel® Server Board S2600JF TPS Term RAM RASUM RISC ROM RTC RMM3 SDR SECC SEEPROM SEL SIO SMBus* SMI SMM SMS SNMP TBD TDP TIM UART UDP UHCI URS UTC UUID VID VRD VT Word ZIF Random Access Memory Definition Reliability, Availability, Serviceability, Usability, and Manageability Reduced
  • Intel H2000JF | Technical Product Specification - Page 194
    Intel® Server Board S2600JF TPS Reference Documents Reference Documents  ACPI 3.0: http://www.acpi.info/spec.htm  IPMI 2.0  Data Center Management Interface Specification v1.0, May 1, 2008: www.intel.com/go/dcmi  PCI Bus Power Management Interface Specification 1.1: http://www.pcisig.com/ 
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

Intel
®
Server Board S2600JF
Technical Product Specification
Intel order number G31608-004
Revision 1.3
July 2012
Enterprise Platforms and Services Division - Marketing