Intel MFSYS25V2 Specification Update - Page 16
Summary Tables of Changes - storage controller
View all Intel MFSYS25V2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Enterprise Platforms and Services Division Specification Update Summary Tables of Changes The following tables indicate the errata and the document changes that apply to the Specification Update. Intel intends to fix some of the errata in a future stepping of components, and to account for the other outstanding issues through documentation or specification changes as noted. The tables use the following notations: Doc: Fix: Fixed: No Fix: Intel intends to update the appropriate documentation in a future revision. Intel intends to fix this erratum in the future. This erratum has been previously fixed. There are no plans to fix this erratum. Shaded: This erratum is either new or has been modified from the previous specification update. Table 1. Errata Summary No. Plans Description of Errata 1. No Fix Intel® Compute Module MFS5000SI NIC/Activity LEDs do not display a link status 2. No Fix Remote floppy is not supported 3. Fixed 1024x768 Resolution with color depth set to thousands of colors not supported under Red Hat* Enterprise Linux 5.0 64-bit 4. No Fix NIC Utility dcreate.exe on MFS500SI -003 Resource CD incomplete 5. Fixed Event Log may report SMI Timeout Assertion after server power button is pressed 6. No Fix User is not able to configure different responses to pressing the Server Power button in Microsoft Windows 2008* Enterprise Server Edition. 7. Fixed Dual Intel® Storage Controller configuration not yet supported in the Intel® Modular Server System MFSYS25 (see details below for specific operating system support) 8. Fixed System Fault LED does not come on if smart devices (SCMs, ESMs, etc.) are completely non-functional 9. Fixed Deleting an existing assigned virtual drive may result in GUI action failure 10. Fixed Certain Non-critical Events logged as Critical in GUI 11. Fixed System Fault LED does not turn on for all critical events 12. Fixed Email Alerting not enabled by default for three Critical Events 13. No Fix Removing/Inserting USB devices during BIOS POST or in EFI may cause unexpected system behavior 14. Fixed Simultaneous Remote KVM installs of OS or applications will not successfully complete 15. No Fix Relative and Absolute KVM Mouse Mode not Supported on all Operating System's 16. Fix Compute modules with RAID 6 Virtual Drives Experiencing Slow / No Response 17. Fixed 18. Fixed CONFIRM dialog box action not required to complete requested action Pressing F1 during a KVM session will bring up the local KVM console help not the remote system application help. 8