Intel P4304BT Specification update - Page 11

Intelligent Platform Management Bus IPMB functions on devices

Page 11 highlights

Monthly Specification Update Enterprise Platforms and Services Marketing 4. Intelligent Platform Management Bus (IPMB) functions on devices connected to IPMB connector might not be available on Intel® Server Board S1200BTL Problem Intelligent Platform Management Bus (IPMB) functions on devices connected to IPMB connector might not be available on the Intel® Server Board S1200BTL. Implication The issue has been root caused to a violation of IPMI and PM Bus specification on the IPMB and PM Bus ports. Status This issue is fixed in BMC Revision 01.05. Workaround None. 5. Unable to install Linux SLES* 11 Service Package 1 to iSCSi drive from onboard Intel® 82579 network card Problem Implication Unable to install SLES11* SP1 to iSCSi drive from 82579 network card. SLES11* SP1 doesn't include a driver for Intel® 82579 network cards. Status The issue is under investigation. Workaround N/A. 6. Node Manager does not work with Intel® Core™ Processor i3-2100 series or Intel® Pentium® Processor Problem On Intel® Server Board S1200BTL, node manager is supported with Intel® Xeon® Processor E3-1200 Series, but node manager is not supported with Intel® Core™ Processor i3-2100 series or Intel® Pentium® Processor. Implication Hardware required for CPU power limiting is functional on Intel® Xeon® Processor; it is not functional on Intel® Core™ i3 processor or Intel® Pentium® Processor. Status No Fix. Workaround N/A. 7. Intel® Integrated RAID Module SRMS2LL040 doesn't work Problem OS is installed to the Intel® Integrated RAID module SRMS2LL040 with SATA CDROM (the on-board SATA mode is set to AHCI mode in BIOS Setup), the OS fails to reboot after removing CDROM. Implication The OpROM of SRMS2LL040 is not compatible with the BIOS. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Monthly Specification Update
Enterprise Platforms and Services Marketing
5
4.
Intelligent Platform Management Bus (IPMB) functions on devices
connected to IPMB connector might not be available on Intel
®
Server
Board S1200BTL
Problem
Intelligent Platform Management Bus (IPMB) functions on devices connected to
IPMB connector might not be available on the Intel
®
Server Board S1200BTL.
Implication
The issue has been root caused to a violation of IPMI and PM Bus specification
on the IPMB and PM Bus ports.
Status
This issue is fixed in BMC Revision 01.05.
Workaround
None.
5.
Unable to install Linux SLES* 11 Service Package 1 to iSCSi drive from
onboard Intel
®
82579 network card
Problem
Unable to install SLES11* SP1 to iSCSi drive from 82579 network card.
Implication
SLES11* SP1 doesn’t include a driver for Intel
®
82579 netw
ork
cards.
Status
The issue is under investigation.
Workaround
N/A.
6.
Node Manager does not work with Intel
®
Core™ Processor i3-2100 series
or Intel
®
Pentium
®
Processor
Problem
On Intel
®
Server Board S1200BTL, node manager is supported with Intel
®
Xeon
®
Processor E3-1200 Series, but node manager is not supported with
Intel
®
Core™ Processor i3-2100 series or Intel
®
Pentium
®
Processor.
Implication
Hardware required for CPU power limiting is functional on Intel
®
Xeon
®
Processor; it is not functional on Intel
®
Core™ i3 processor or Intel
®
Pentium
®
Processor.
Status
No Fix.
Workaround
N/A.
7.
Intel
®
Integrated RAID Module SRMS2LL040 doesn’t work
Problem
OS is installed to the Intel
®
Integrated RAID module SRMS2LL040 with SATA
CDROM (the on-board SATA mode is set to AHCI mode in BIOS Setup), the
OS fails to reboot after removing CDROM.
Implication