Intel R1000GZ Monthly Specification Update - Page 7
Summary Tables of Changes
View all Intel R1000GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Monthly Specification Update Enterprise Platforms and Services Marketing Summary Tables of Changes The following tables provide an overview of known errata and known document changes that apply to the specified Intel Server Products. The tables use the following notations: Doc: Intel intends to update the appropriate documentation in a future revision. Fix: Intel intends to fix this erratum in the future. Fixed: This erratum has been previously fixed. No Fix: There are no plans to fix this erratum. Shaded: This erratum is either new or has been modified from the previous specification update. No. Plans Table 1. Errata Summary Description of Errata 1. Fix Linux* Operating Systems are not supported on RSTe mode 2. Fixed UEFI Windows Server 2008* R2 SP1 installation on SCU ports may fail under RSTe RAID mode 3. Fix UEFI Operating System installation is not supported on ESRT2 mode 4. Fixed HDD status LEDs do not function under specific configuration 5. Fixed RSTe GUI installation may fail if there are no devices attached to any onboard AHCI ports 6. Fixed BMC continuously sends RAID volume rebuild event in RSTe mode of the SCU controller 7. Fixed System may halt under specific BIOS configurations 8. Fix Microsoft Windows 2003* x86 installation failure under Pass-through mode of SCU controller 9. Fixed System may halt under unsupported configuration in ESRT2 mode 10. Fixed Integrated BMC Web Console - Power Statistics page - Minimum wattage reads as zero 11. Fixed Integrated BMC Web Console - Power Control page - Perform Action button not functional. 12. Fixed IPMI Get Chassis Status command returns incorrect Chassis Identify State 13. Fixed The BIOS and ME Firmware can't be updated successfully via Intel® One Boot Flash Update Utility(OFU) under SuSE* Linux Enterprise Server 11* (64-bit) with SP2 14. Fixed BMC continuously sends HDD assert/de-assert event during HDD RAID rebuild under ESRT2 mode of the SCU controller 15. Fix Hard drives connected through SAS expander can't be detected in legacy mode 16. Fixed Intel® RAID C600 Upgrade Key replacement Issue 17. Fixed Intel® LAN driver installation failure on Windows* 7 18. Fixed On-board VGA cannot be set to the highest resolution (1920x1080 and higher) 19. Fixed Hard drive locate LED may not instantly respond to the locate command if backplane is connected through SAS expander to a RAID controller 20. Fix Integrated BMC Web Console - Sensor Readings Page - Memory Throttling sensor status will stay "Critical" once triggered 21. Fixed WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS 22. Fixed POST Code Diagnostic LEDs may not be all off after POST has completed 23. Fixed System only reports the first occurrence of power redundancy loss 24. Fixed System fan speed may not slow down as expected after hot-swapping a failed fan within the Intel® Server System R2000GZ/GL Product Family 2