Intel R2000WT System Integration and Service Guide - Page 66

SATA RAID 5 Upgrade Key – Installation / Removal, 3.6.1 Installing the SATA RAID 5 Upgrade Key

Page 66 highlights

Intel® Server System R2000WT Product Family System Integration and Service Guide 4. Remove the three screws as shown (see letter 'A'). 5. Carefully pull up on the I/O Module until it disengages from the server board (see letter 'B'). 6. If no replacement module is to be installed, re-install the I/O expansion module bay filler panel into the system back panel (Note: the filler panel snaps into the back panel from the outside of the chassis) 3.6 SATA RAID 5 Upgrade Key - Installation / Removal 3.6.1 Installing the SATA RAID 5 Upgrade Key Figure 65. Installing the SATA RAID 5 Upgrade Key 1. Remove the SATA 5 Upgrade Key from its packaging 2. Locate the white 4-pin key connector behind the onboard NIC 2 port on the back edge of the server board. 3. To install the key, place it over the connector and confirm the orientation of the key matches that of the connector 4. Press the key down onto the connector. 3.6.2 Removing the SATA RAID 5 Upgrade Key 1. Power off the system and disconnect the power cable(s) 2. Remove the system cover (see section 2.2.1) 3. Using the Key pull tab, pull the key up until it disengages from the connector 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

Intel
®
Server System R2000WT Product Family System Integration and Service Guide
50
4.
Remove the three screws as shown (see letter ‘A’).
5.
Carefully pull up on the I/O Module until it disengages from the server board (see letter ‘B’).
6.
If no replacement module is to be installed, re-install the I/O expansion module bay filler panel into
the system back panel
(Note: the filler panel snaps into the back panel from the outside of the
chassis)
3.6
SATA RAID 5 Upgrade Key – Installation / Removal
3.6.1
Installing the SATA RAID 5 Upgrade Key
Figure 65. Installing the SATA RAID 5 Upgrade Key
1.
Remove the SATA 5 Upgrade Key from its packaging
2.
Locate the white 4-pin key connector behind the onboard NIC 2 port on the back edge of the server
board.
3.
To install the key, place it over the connector and confirm the orientation of the key matches that of
the connector
4.
Press the key down onto the connector.
3.6.2
Removing the SATA RAID 5 Upgrade Key
1.
Power off the system and disconnect the power cable(s)
2.
Remove the system cover (see section 2.2.1)
3.
Using the Key pull tab, pull the key up until it disengages from the connector