Intel RS3FC044 User Guide - Page 19

Mirrored Volume Features, Resynchronization with Concurrent Host I/O Operation, Hot Swapping

Page 19 highlights

Mirrored Volume Features This section describes features of Integrated Mirroring volumes, Integrated Mirroring + Striping volumes, and Integrated Mirroring Enhanced volumes. Resynchronization with Concurrent Host I/O Operation The Integrated RAID firmware permits host I/O transactions to continue on a mirrored volume while it resynchronizes the volume in the background. The firmware automatically starts resynchronizing data after a disk failure activates a hot spare, or after a disk in a mirrored volume has been hot-swapped. Hot Swapping The Integrated RAID firmware supports hot swapping, and it automatically resynchronizes the hot-swapped disk in the background without any host or user intervention. The firmware detects hot-swap removal and disk insertion. Following a hot-swap event, the firmware verifies that the new physical disk has enough capacity for the mirrored volume. The firmware resynchronizes all replaced hot-swapped disks, even if the same disk is removed and then re-inserted. In a mirrored volume with an even number of disks, the firmware marks the hot-swapped disk as a secondary disk and the other disk with data as the primary disk. The firmware resynchronizes all data from the primary disk onto the new secondary disk. In a mirrored volume with an odd number of disks, primary and secondary sets include three disks instead of two disks. Hot Spare Disk You can configure two disks as global hot spare disks to protect data on the mirrored volumes configured on the SAS-3 controller. If the Integrated RAID firmware fails one of the mirrored disks, it automatically replaces the failed disk with a hot spare disk and then resynchronizes the mirrored data. The firmware automatically receives a notification when a hot spare replaces the failed disk, and it then designates that disk as the new hot spare. Online Capacity Expansion The OCE feature enables you to expand the capacity of an existing two-disk Integrated Mirroring (RAID 1) volume by replacing the original disk drives with higher-capacity drives that have the same protocol (SAS or SATA). Note: The replacement drives must have at least 50 GB more capacity than the original drives of the volume. Intel® Integrated RAID Solution User Guide 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

IntelĀ®
Integrated RAID Solution User Guide
9
Mirrored Volume Features
This section describes features of Integrated Mirroring volumes, Integrated Mirroring +
Striping volumes, and Integrated Mirroring Enhanced volumes.
Resynchronization with Concurrent Host I/O Operation
The Integrated RAID firmware permits host I/O transactions to continue on a mirrored
volume while it resynchronizes the volume in the background. The firmware
automatically starts resynchronizing data after a disk failure activates a hot spare, or after
a disk in a mirrored volume has been hot-swapped.
Hot Swapping
The Integrated RAID firmware supports hot swapping, and it automatically
resynchronizes the hot-swapped disk in the background without any host or user
intervention. The firmware detects hot-swap removal and disk insertion.
Following a hot-swap event, the firmware verifies that the new physical disk has enough
capacity for the mirrored volume. The firmware resynchronizes all replaced hot-swapped
disks, even if the same disk is removed and then re-inserted. In a mirrored volume with an
even number of disks, the firmware marks the hot-swapped disk as a secondary disk and
the other disk with data as the primary disk. The firmware resynchronizes all data from the
primary disk onto the new secondary disk. In a mirrored volume with an odd number of
disks, primary and secondary sets include three disks instead of two disks.
Hot Spare Disk
You can configure two disks as global hot spare disks to protect data on the mirrored
volumes configured on the SAS-3 controller. If the Integrated RAID firmware fails one of
the mirrored disks, it automatically replaces the failed disk with a hot spare disk and then
resynchronizes the mirrored data. The firmware automatically receives a notification
when a hot spare replaces the failed disk, and it then designates that disk as the new hot
spare.
Online Capacity Expansion
The OCE feature enables you to expand the capacity of an existing two-disk Integrated
Mirroring (RAID 1) volume by replacing the original disk drives with higher-capacity
drives that have the same protocol (SAS or SATA).
Note:
The replacement drives must have at least 50 GB more capacity than the original drives of
the volume.