Intel S3200SH Technical Product Specification - Page 50

Appendix A: Integration and Usage Tips - server motherboard

Page 50 highlights

Appendix A: Integration and Usage Tips Intel® Server Systems SR1530SH and SR1530HSH Appendix A: Integration and Usage Tips This section provides a list of useful information unique to the Intel® Server Chassis SR1530 and should be kept in mind while integrating and configuring the Intel® Server Board S3200SHL. • You can use only low-profile (1.2 inch or 30.48 mm) DIMMs in the server chassis. • Processor fans are not needed and are not supported. The system fan module and power supply fans provide the required cooling for the system. Using a processor fan in this chassis may cause the Intel® System Management Software to incorrectly monitor the system fans. • You must use the air duct to maintain system thermals. • System fans are not hot-swappable. • A screw on the front edge of the top cover is required when the unit is installed in a user- accessible environment. • Make sure the latest system software is loaded. This includes system BIOS. You can download the latest system software from: http://support.intel.com/support/motherboards/server/S3200SH/. 42 Intel order number: E23177-003 Revision 1.3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

Appendix A: Integration and Usage Tips
Intel® Server Systems SR1530SH and SR1530HSH
Intel order number: E23177-003
Revision 1.3
42
Appendix A: Integration and Usage Tips
This section provides a list of useful information unique to the Intel
®
Server Chassis SR1530
and should be kept in mind while integrating and configuring the Intel
®
Server Board S3200SHL.
You can use only low-profile (1.2 inch or 30.48 mm) DIMMs in the server chassis.
Processor fans are not needed and are not supported. The system fan module and
power supply fans provide the required cooling for the system. Using a processor fan in
this chassis may cause the Intel
®
System Management Software to incorrectly monitor
the system fans.
You must use the air duct to maintain system thermals.
System fans are not hot-swappable.
A screw on the front edge of the top cover is required when the unit is installed in a user-
accessible environment.
Make sure the latest system software is loaded. This includes system BIOS. You can
download the latest system software from:
.