Intel S5000XSL Specification Update - Page 29

S5000PSLSAS software RAID 5 cannot be con d

Page 29 highlights

Monthly Specification Update Enterprise Platforms and Services Marketing Workaround revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision -v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I. None. 38. POST screen may generate "NMI has been received - System Halted" message after the system reboots Problem POST screen may generate "NMI has been received - System Halted" message after the system reboots. Implication Along with this error, sometimes "Bus Uncorrectable Error" might also be recorded to System Event Log (SEL). Status Workaround This erratum is fixed in BIOS release R0066 and later releases. Reboot the system again. 39. S5000PSLSAS software RAID 5 cannot be configured Problem Implication Status Workaround When users install the SAS software RAID 5 key on the board, there is no SAS software RAID 5 option that displays in the SAS RAID configuration menu. This problem may occur because of old versions of SAS RAID firmware on the server board. This erratum was fixed in Intel® Embedded Server RAID Technology II firmware revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision -v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I. None. 40. SuSE* Linux Enterprise Server unable to boot after basic installation Problem During a SuSE* Linux Enterprise Server installation, if a USB floppy drive is used to load the mass storage driver, SuSE* Linux Enterprise Server may not boot after basic installation. The following message may display: resume device /dev/sdb1 not found (ignoring) waiting for device /dev/sdb2 to appear not found -- exiting to /bin/sh $ 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Monthly Specification Update
Enterprise Platforms and Services Marketing
21
revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision --
v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I.
Workaround
None.
38.
POST screen may generate “NMI has been received – System Halted”
message after the system reboots
Problem
POST screen may generate "NMI has been received - System Halted"
message after the system reboots.
Implication
Along with this error, sometimes “Bus Uncorrectable Error” might also be
recorded to System Event Log (SEL).
Status
This erratum is fixed in BIOS release R0066 and later releases.
Workaround
Reboot the system again.
39.
S5000PSLSAS software RAID 5 cannot be configured
Problem
When users install the SAS software RAID 5 key on the board, there is no SAS
software RAID 5 option that displays in the SAS RAID configuration menu.
Implication
This problem may occur because of old versions of SAS RAID firmware on the
server board.
Status
This erratum was fixed in Intel
®
Embedded Server RAID Technology II firmware
revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision --
v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I.
Workaround
None.
40.
SuSE* Linux Enterprise Server unable to boot after basic installation
Problem
During a SuSE* Linux Enterprise Server installation, if a USB floppy drive is
used to load the mass storage driver, SuSE* Linux Enterprise Server may not
boot after basic installation. The following message may display:
resume device /dev/sdb1 not found (ignoring)
waiting for device /dev/sdb2 to
appear
..............................
not found -- exiting
to /bin/sh
$