Intel SRCSASRB Hardware User Guide - Page 8

Redundancy and Error Handling, Failures are logged in NVRAM, viewable from OS Event Log, Intel - performance

Page 8 highlights

• Advanced Array configuration and Management Utilities provides: - Online Capacity Expansion (OCE) adds space to existing drive or new drive. See Appendix A for limitations on OCE and RAID migration. - Online RAID level migration (upgrade of RAID mode, may require OCE). - Drive migration. - Drive roaming. - No reboot necessary after expansion. • Upgradeable Flash ROM interface. • Allows for staggered spin up, hot-plug, and lower power consumption. • User specified rebuild rate (percent of system resources to use from 0-100%). Caution: Exceeding 50% rate may cause operating system errors due to waiting for controller access. • Background operating mode can be set for Rebuilds, Consistency Checks, Initialization (auto restarting Consistency Check on redundant volumes); Migration, OCE, and Patrol Read. Redundancy and Error Handling • In-band and out-of-band SES2. • Enclosure management support. • Fault indicators per drive. • Drive coercion (auto-resizing to match existing disks). • Auto-detection of failed drives with transparent rebuild. There must be disk activity (I/O to the drive) for a missing drive to be marked as failed. • Auto-resume on reboot of initialization or rebuild (must be enabled before virtual disk creation). • Smart initialization automatically checks consistency of virtual disks if there are five or more disks in a RAID 5 array, which optimizes performance by enabling readmodify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode. • Dirty cache LED plus error reporting for cache write to disk. • Smart Technology predicts failures of drives and electronic components. • Patrol Read checks drives and maps bad sectors. • Commands are retried at least four times. • Firmware provides best effort to recognize an error and recover if possible. • Failures are logged from controller and drive firmware, and SMART monitor. • Failures are logged in NVRAM, viewable from OS Event Log, Intel® RAID Web Console 2; CIM, LEDs, and via alarm. 3 Intel® RAID Controller SRCSASRB Hardware User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

3
Intel® RAID Controller SRCSASRB Hardware User’s Guide
Advanced Array configuration and Management Utilities provides:
Online Capacity Expansion (OCE) adds space to existing drive or new drive.
See Appendix A for limitations on OCE and RAID migration.
Online RAID level migration (upgrade of RAID mode, may require OCE).
Drive migration.
Drive roaming.
No reboot necessary after expansion.
Upgradeable Flash ROM interface.
Allows for staggered spin up, hot-plug, and lower power consumption.
User specified rebuild rate (percent of system resources to use from 0-100%).
Caution:
Exceeding 50% rate may cause operating system errors due to waiting for
controller access.
Background operating mode can be set for Rebuilds, Consistency Checks,
Initialization (auto restarting Consistency Check on redundant volumes); Migration,
OCE, and Patrol Read.
Redundancy and Error Handling
In-band and out-of-band SES2.
Enclosure management support.
Fault indicators per drive.
Drive coercion (auto-resizing to match existing disks).
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
Dirty cache LED plus error reporting for cache write to disk.
Smart Technology predicts failures of drives and electronic components.
Patrol Read checks drives and maps bad sectors.
Commands are retried at least four times.
Firmware provides best effort to recognize an error and recover if possible.
Failures are logged from controller and drive firmware, and SMART monitor.
Failures are logged in NVRAM, viewable from OS Event Log, Intel
®
RAID Web
Console 2; CIM, LEDs, and via alarm.