Intermec PF2i Intermec Direct Protocol 8.60 Programmer's Reference Manual - Page 40

Barfont, On | Barfont, Off[, <nexp>], On | Bf, Pp 100, 100:an 7:dir 4:barset Code39

Page 40 highlights

Chapter 3-Label Design enables printing of bar code interpretation (default: OFF) All parameters reset to default by PRINTFEED (PF) Bar code interpretation printing can also be enabled or disabled using these instructions: BARFONT ↔ON | BARFONT↔OFF[,] BF ↔ON | BF↔OFF[,] By default, bar code interpretation is disabled. When printing EAN/UPC codes, the trailing parameter 0 can be specified to disable the printing of guard bars. BARFONT OFF or BARFONT OFF,1 returns the settings to the default. Summary To create a bar code field, the following formatting instructions must be given (in most cases default values may substitute missing parameters). Input data and printing instructions are explained in Chapters 3.9 and 4.2 respectively. Purpose Instruction Default Remarks X/Y Position PP (PRPOS) Alignment AN (ALIGN) Direction DIR Bar Code Select BARSET Interpretation BF...ON 0/0 1 1 see above Off Number of dots Select ALIGN 1-9 Select DIR 1-4 Can be replaced by BT, BH, BR, BM Can be omitted Example: PP 100,100:AN 7:DIR 4:BARSET "CODE39",2,1,3,120: BF #2,"Swiss 721 BT",5,1,1 ON ↵ 32 Intermec Direct Protocol v.8.60-Programmer's Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

32
Intermec Direct Protocol v.8.60—Programmer’s Reference Manual
Chapter 3—Label Design
<ON>
enables printing of bar code interpretation (default: OFF)
All parameters reset to default by PRINTFEED (PF)
Bar code interpretation printing can also be enabled or disabled using
these instructions:
BARFONT
ON | BARFONT
OFF[,<nexp>]
BF
ON | BF
OFF[,<nexp>]
By default, bar code interpretation is disabled. When printing EAN/UPC codes, the trailing parameter
0 can be specified to disable the printing of guard bars. BARFONT OFF or BARFONT OFF,1 returns the
settings to the default.
Summary
To create a bar code field, the following formatting instructions must be
given (in most cases default values may substitute missing parameters).
Input data and printing instructions are explained in Chapters 3.9 and
4.2 respectively.
Purpose
Instruction
Default
Remarks
X/Y Position
PP (PRPOS)
0/0
Number of dots
Alignment
AN (ALIGN)
1
Select ALIGN 1-9
Direction
DIR
1
Select DIR 1-4
Bar Code Select BARSET
see above
Can be replaced by
BT, BH, BR, BM
Interpretation
BF...ON
Off
Can be omitted
Example:
PP 100,100:AN 7:DIR 4:BARSET "CODE39",2,1,3,120:
BF #2,"Swiss 721 BT",5,1,1 ON