Cleaning

Page 71 highlights

q Inspect seat positioning strap for any signs of wear. Ensure buckle latches. Verify hardware that attaches strap to frame is secure and undamaged. Replace if necessary. q Check center mount front riggings for loose fasteners. Replace /tighten if necessary. q Cables shall be inspected periodically to ensure that they are routed and secured properly. Ensure that cables do NOT become entangled and damaged during normal operation of the seating system. Periodic inspection is recommended as it may reveal loose and/or damaged cables. Re-secure all loose cables and replace by following the recommendations outlined in the LiNX Controls System Service Manual. q Ensure proper operation of powered functions (drive, seating, legrests, etc.). q Inspect electrical components for signs of corrosion. Replace if corroded or damaged. q Clean upholstery and armrests. q Check that all labels are present and legible. Replace if necessary. q Ensure clothing guards are secure. q Ensure upholstery does not have any rips or tears. q Ensure armrest pad sits flush against arm tube. q Inspect all fasteners including the back pan, back cane and angle adjustment fasteners, and the arm support, flip back and height adjustment fasteners. Ensure fasteners are securely tightened. q Inspect TRRO fasteners and hardware. q Inspect foam handgrips for damage. If damaged, have them replaced by a qualified technician. 60101832-A Maintenance q Check power center mount front riggings for worn/frayed belts and/or loose fasteners. If found, replace these items. q Make sure all electrical connections are secure. q Make sure drive lock-out operates properly. q Check limit switch position. q Make sure seating systems with the recline function have the retaining pin in place at the top of each back cane. q Make sure all systems have the retaining pin in place at the back of each seat rail. q Check that spreader bar mounting fasteners are tight. 7.4 Cleaning WARNING! Risk of Injury, Damage or Death Electrical shock may cause injury, damage or death. - Always unplug the product from the electrical outlet before cleaning. - Always unplug accessories from the electrical outlet before cleaning. CAUTION! Risk of Damage Cleaning or maintenance may cause damage to carpeting or flooring. - Place the wheelchair in a well ventilated area where cleaning or maintenance can be performed without risk of damage to carpeting or flooring. 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

Maintenance
q
Inspect seat positioning strap for any signs of wear.
Ensure buckle latches. Verify hardware that attaches
strap to frame is secure and undamaged. Replace if
necessary.
q
Check center mount front riggings for loose fasteners.
Replace /tighten if necessary.
q
Cables shall be inspected periodically to ensure that
they are routed and secured properly. Ensure that
cables do NOT become entangled and damaged during
normal operation of the seating system. Periodic
inspection is recommended as it may reveal loose
and/or damaged cables. Re-secure all loose cables and
replace by following the recommendations outlined in
the LiNX Controls System Service Manual.
q
Ensure proper operation of powered functions (drive,
seating, legrests, etc.).
q
Inspect electrical components for signs of corrosion.
Replace if corroded or damaged.
q
Clean upholstery and armrests.
q
Check that all labels are present and legible. Replace
if necessary.
q
Ensure clothing guards are secure.
q
Ensure upholstery does not have any rips or tears.
q
Ensure armrest pad sits flush against arm tube.
q
Inspect all fasteners including the back pan, back cane
and angle adjustment fasteners, and the arm support,
flip back and height adjustment fasteners. Ensure
fasteners are securely tightened.
q
Inspect TRRO fasteners and hardware.
q
Inspect foam handgrips for damage. If damaged, have
them replaced by a qualified technician.
q
Check power center mount front riggings for
worn/frayed belts and/or loose fasteners. If found,
replace these items.
q
Make sure all electrical connections are secure.
q
Make sure drive lock-out operates properly.
q
Check limit switch position.
q
Make sure seating systems with the recline function
have the retaining pin in place at the top of each back
cane.
q
Make sure all systems have the retaining pin in place at
the back of each seat rail.
q
Check that spreader bar mounting fasteners are tight.
7.4
Cleaning
WARNING!
Risk of Injury, Damage or Death
Electrical shock may cause injury, damage or
death.
– Always unplug the product from the electrical
outlet before cleaning.
– Always unplug accessories from the electrical
outlet before cleaning.
CAUTION!
Risk of Damage
Cleaning or maintenance may cause damage to
carpeting or flooring.
– Place the wheelchair in a well ventilated
area where cleaning or maintenance can be
performed without risk of damage to carpeting
or flooring.
60101832-A