JET Tools JAT-501 User Manual - Page 11
Replacement parts
View all JET Tools JAT-501 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Problem Gun leaks from fluid nozzle. Paint emerges from needle packing. Too much overspray. "Orange peel" finish (textured instead of smooth). Possible cause Foreign substances between fluid nozzle and needle. Needle packing is damaged or missing. Gun too far away. Excessive fluid. Excessive air pressure. Nozzle too large for project. Insufficient air pressure for proper atomization. Fluid too thick. Applying fluid at an angle. Remedy Disassemble and clean nozzle and needle. Replace packing. Move gun closer to work surface. Reduce fluid flow. Reduce air flow. Try smaller nozzle kit. Increase air flow. Thin the fluid and retry. Apply perpendicular to work surface. Replacement parts Service parts are listed on the following pages. To order parts or reach our service department, call 1-800274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Please have the stock number and serial number of your tool available when you call, so that we may serve you quickly and accurately. JET 11