JVC DLA-M2000LU Serial protocol for the DLA-DS1U and DLA-M2000LU/SC D-ILA proj - Page 27
R-Gain
View all JVC DLA-M2000LU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
12.12 R-Gain :'U0C'(55H 30H 43H) Definition :Adjusts the R-gain Command Parameter type Reply time Conditions :'U0C'(55H 30H 43H) :Numeric, :3seconds :Computer Sources (Areas) Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When specifying "-2" (decimal) as the R-gain adjust level CTLR DLA '!' '1' SP 'U0C' SP 'FFFE' CR '@' '1' SP '0' CR ◇ When requesting current R-gain adjust level data (if R-gain adjust level is set to "128" (decimal)) CTLR DLA '?' '1' SP 'U0C' CR '@' '1' SP '0' SP '0080' CR 26
26
12.12
R-Gain
:
’
U0C
’
(55H
30H
43H)
Definition
:
Adjusts the R-gain
Command
:
’U0C’(55H
30H
43H)
Parameter type
:
Numeric,
Reply time
:
3seconds
Conditions
:
Computer Sources (Areas)
Operation mode
Standby mode
Power ON mode
Cool-down mode
Emergency mode
X
O
X
X
#
Communication Examples
◇
When specifying "-2" (decimal) as the R-gain adjust level
CTLR
‘!’
‘1’
SP
‘U0C’
SP
‘FFFE’
CR
DLA
‘@’
‘1’
SP
‘0’
CR
◇
When requesting current R-gain adjust level data (if R-gain adjust level is set to "128" (decimal))
CTLR
‘?’
‘1’
SP
‘U0C’
CR
DLA
‘@’
‘1’
SP
‘0’
SP
‘0080’
CR