Jenn-Air CVGX2423B Installation Instruction - Page 11
Installation of LP Orifice, Spuds - reviews
View all Jenn-Air CVGX2423B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Installation of LP Orifice Spuds With a quarter, engage slot and rotate cap 1/8 of a turn counterclockwise. To remove cap, turn cap over and reinstall. Figure 6 B. Invert Cap in Appliance Pressure Regulator (See figures 7 and 8.) With the appliance installed, the regulator is located on the underside of the burner box on the right hand side at the inlet to the gas manifold. Identify the make of appliance regulator on the unit and follow the instructions in the appropriate illustration. Figure 8: Conversion of Harper-Wyman Appliance Pressure Regulator After conversion, steps A and B have been completed, check the appearance of each burners' flame at the Hi and Lo settings against figure 9. If the flames appear too large or too small, review all steps to make sure they were completed correctly. Figure 7: Conversion of Maxitrol Appliance Pressure Regulator Figure 9: Flame Appearance at Hi and Lo 6