Jenn-Air JDRP436WP Dimension Guide - Page 1
Jenn-Air JDRP436WP Manual
![]() |
View all Jenn-Air JDRP436WP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
30" (76.2 CM), 36" (91.4 CM) AND 48" (121.9 CM) COMMERCIAL STYLE DUAL FUEL CONVECTION RANGES PRODUCT MODEL NUMBERS LOCATION REQUIREMENTS JDRP430W JDRP436W JDRP536W JDRP548W ELECTRICAL REQUIREMENTS - U.S.A. ONLY To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. q Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located under the console on the right-hand side. Refer to the figures in the "Product Dimensions" section of the "Location Requirements" section. q This range may be manufactured with a 4-wire power supply cord or may not include a power supply cord. If your range does not include a power supply cord, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges. Mobile Home - Additional Installation Requirements The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes. In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or with local codes. Mobile home installations require: q When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above. Range Rating* Specified Rating of Power Supply Cord Kit and Circuit Protection PRODUCT DIMENSIONS 120/240 Volts 120/208 Volts Amps Range Size 30" (76.2 cm) models 8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50** 30" (76.2 cm), A 36" (91.4 cm) 16.6 - 22.5 KW 12.6 - 18.5 KW 50 48" (121.9 cm) B ** The NEC calculated load is less than the total connected load listed on the model/serial rating plate. ** If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening. q A circuit breaker is recommended. q Wire sizes and connections must conform with the rating of the range. ELECTRICAL REQUIREMENTS - CANADA ONLY q Check with a qualified electrical installer if you are not sure the range is properly grounded. C q When a 4-wire, single phase 250 volt, 60 Hz., AC only electrical supply is available, a 40-amp minimum circuit protection is required on 30" (76.2 cm) and 36" (91.4 cm) ranges and a 50-amp minimum circuit protections is required on 48" (121.9 cm) ranges, fused on both sides of the line. q A time-delay fuse or circuit breaker is recommended. q This range is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range's final location. E D q Do not use an extension cord. GAS SUPPLY REQUIREMENTS Type of Gas Natural Gas: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. q This range is factory set for use with Natural gas. The model/serial rating plate located under the console on the right-hand side has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. LP Gas conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the range from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. To convert to LP gas, use the LP gas conversion kit provided with your range and see the "Gas Conversions" section. The parts for this kit are in the literature package supplied with the range. Gas Supply Line q Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 1 of 2 Ref. W10349768A 1/4/11
![](/manual_guide/products/jennair-jdrp430wp-dimension-guide-1e5c5a0/1.png)