Natural Gas Conversion
![]() |
View all Jenn-Air JDRP436WP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
7. Place Natural gas orifice in plastic parts bag for future use and keep with package containing literature. 8. Replace the burner base using both screws. 9. Replace burner head and cap. 10. Repeat steps 2 through 9 for the remaining burners. Complete Installation 1. Refer to the "Make Gas Connection" section for properly connecting the range to the gas supply. 2. Refer to the "Electronic Ignition System" section for proper burner ignition, operation, and burner flame adjustments. IMPORTANT: You may have to adjust the "LO" setting for each cooktop burner. Checking for proper cooktop burner flame is very important. The small inner cone should have a very distinct blue flame ¼" (0.64 cm) to ½" (1.3 cm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. Natural Gas Conversion WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. 1. Turn manual shutoff valve to the closed position. B A C A. To range B. Shutoff valve (closed position) C. Gas supply line 2. Unplug range or disconnect power. To Convert Gas Pressure Regulator 1. Remove the access cap by using a wrench, turning the access cap counterclockwise. 2. Remove spring retainer from the cap by pushing against the flat side of the spring retainer. Look at the spring retainer to locate the "LP" or "NAT" position. Turn over the spring retainer so the "NAT" is showing on the bottom. Snap the spring retainer back into the cap. Reinstall the cap onto the regulator. A B E D C A. Access cap B. Gasket C. Gas pressure regulator D. NAT position E. LP position 3. Test the gas pressure regulator and gas supply line. The regulator must be checked at a minimum 1" (2.5 cm) water column above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting: Natural Gas: Minimum pressure 6" (15.2 cm) WCP Maximum pressure 14" (35.6 cm) WCP Gas Supply Pressure Testing Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate. Line pressure testing above ½ psi gauge (14" WCP) The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa). Line pressure testing at ½ psi gauge (14" WCP) or lower The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa). 17
![](/manual_guide/products/jennair-jdrp436wp-installation-instruction-8d6b357/17.png)