Jenn-Air JDS1750F Dimension Guide - Page 3

Front View - Rear Wall Venting Option, Back View, Side View, Top View - Cutout

Page 3 highlights

JENN-AIR® DETAILED PLANNING DIMENSIONS 30" DUAL-FUEL DOWNDRAFT RANGE JDS1750F - 297⁄8" x 36" x 285⁄16" 3 of 4 OPENING/CLEARANCE DIMENSIONS A CD E H* B A F G H* I B I BD E C C J Ag e v† FG K FRONT VIEW - REAR WALL VENTING OPTION J K SidSiede CaCbaibnientet LL MODEL # JDS1750F in cm A Width of combustible area above cooking surface (min.) 30 76.2 B Width from cooktop to fixed wall or other combustible material (min.) 3 7.6 C Width from electrical installation area to cabinet (min.) D Width from vent inCsaStbiadineleltation area to left side of cabinet (min.) E Width from vent instLallation area to right side of cabinet (min.) 413⁄16 12.2 12 30.5 8 20.3 F Height of center of rear wall vent installation area (max) G G Height of sides of rear wall vent installaHtion area (max) H* Height to bottom of uncovered wood oI r metal cabinet above cooking surface (min.) 71⁄2 19.0 51⁄2 14.0 30 v‡ 76.2 I Height to bottom of uncovered wood or metal cabinet (min.) J Height of electrical installation area (max.) K Depth of electrAic*al installation area (max.) B* L Depth of upper cabCi*net (recommended) M Width of cutout (minD.*) 18 45.7 711⁄16 M 19.5 311⁄16 9.4 13 E* 33.0 F* 30 76.2 e Recommended junction box location (within shaded dashed line area) g Recommended gas access location v† Recommended rear wall venting location (within patterned solid line area) - see page 4 for ducting information v‡ Refer to template number W10817089B - see page 4 for ducting information J *Dimension can be reduced by 6" (15.2 cm) when botKtom of wood or metal cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. ELECTRICAL REQUIREMENTS 240 volt, 60 Hz, AC only, 40-amp fused, grounded circuit is required. A dedicated circuit is recommended. Minimum length of power cord is 48" (121.9 cm). aa vv‡ ‡ bb WWalal ll dd ee vv f f M M CaSCbiadSibniedienetet cc CaSCbiadSibniedienetet L SIDE VIEW TOP VIEW - CUTOUT BACK VIEW IMPORTANT: Dimensional specifications are provided for planning purposes only. Dbeofonroetsemleacktiengancaybcinuettoryu, tvserbifaysinegdeolencttrhiciasl/ignafsocromnanteiMcotnio.nRse,fmeratkointghecuIntostuatlslaotirobneogrinUnsieng&inCsatraellaGtuioidne. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8894BdZw916

  • 1
  • 2
  • 3
  • 4

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
3 of 4
8894BdZw916
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation or Use & Care Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
30" DUAL-FUEL DOWNDRAFT RANGE
JDS1750F – 29
7
8
" x 36" x 28
5
16
"
OPENING/CLEARANCE DIMENSIONS
MODEL #
JDS1750F
in
cm
A
Width of combustible area above cooking
surface (min.)
30
76.2
B
Width from cooktop to fixed wall or other
combustible material (min.)
3
7.6
C
Width from electrical installation area
to cabinet (min.)
4
13
16
12.2
D
Width from vent installation area to left side
of cabinet (min.)
12
30.5
E
Width from vent installation area to right side
of cabinet (min.)
8
20.3
F
Height of center of rear wall vent installation
area (max)
7
1
2
19.0
G
Height of sides of rear wall vent installation area (max)
5
1
2
14.0
H*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
30
76.2
I
Height to bottom of uncovered wood
or metal cabinet (min.)
18
45.7
J
Height of electrical installation area (max.)
7
11
16
19.5
K
Depth of electrical installation area (max.)
3
11
16
9.4
L
Depth of upper cabinet (recommended)
13
33.0
M
Width of cutout (min.)
30
76.2
e
Recommended junction box location (within shaded dashed line area)
g
Recommended gas access location
v
Recommended rear wall venting location (within patterned solid line
area) – see page 4 for ducting information
v
Refer to template number W10817089B – see page 4 for
ducting information
*Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet
is covered by not less than
1
4
" (0.6 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
ELECTRICAL REQUIREMENTS
240 volt, 60 Hz, AC only, 40-amp fused, grounded circuit is required. A dedicated
circuit is recommended. Minimum length of power cord is 48" (121.9 cm).
M
v
v
Side
Cabinet
L
H*
I
A
B
B
K
J
v
D
E
C
C
J
F
F
G
G
v
e
g
e
g
FRONT VIEW – REAR WALL VENTING OPTION
BACK VIEW
SIDE VIEW
TOP VIEW – CUTOUT