Dual Fuel Updraft Slide-in Range PRODUCT MODEL NUMBERS JDS8860BD Gas supply: Natural gas supply line must have a natural gas service regulator. Inlet pressure to this appliance should be reduced to a maximum of 14" water column (0.5 pounds per square inch (p.s.i.) liquefied petroleum propane gas supply line must have a L.P. gas pressure regulator. Inlet pressure to this appliance should be reduced to a maximum of 14" water column (0.5 p.s.i.). Inlet pressures in excess of 0.5 p.s.i. can damage the appliance pressure regulator and other gas components in this appliance and can result in a gas leak. NOTE: It is recommended to use a CSA certified flexible connector no longer than 36" (91.4 cm) with a minimum BTU/HR rating of 88,200. A gas shutoff valve should be put in an accessible location in the supply line ahead of the range, for turning on and turning off gas supply. Range is to be connected to house piping with flexible metal connectors for gas appliances. Connector nuts must not be connected directly to pipe threads. The connectors must be installed with adapters provided with the connector. Electrical: This range requires a single-phase three-wire 120/240- or a 120/208-volt, 60-Hz, AC-circuit. Wiring codes require a separate circuit be run from the main entrance panel to the range and that it be equipped with separate disconnect switch and fuses, either in the main entrance panel or in a separate switch and fuse box. CLEARANCE DIMENSIONS WCoamll bCuasbtiinbelets/ (3133cm" ) 13" (33 cm) Max. Depth of cabinets above cooktop (415.78c"m) (736.20c""m) 3(7".6 cm) (415.78c"m) (623.55c"m) 3(7".6 cm) BCoumildbinugstWiblaells Range may be installed with zero inches clearance adjacent to (against) combustible construction at the rear and on the sides below the cooktop. For complete information in regard to the installation of wall cabinets above the range and clearances to combustible wall above the cooking top see the installation drawings. For SAFETY CONSIDERATIONS do not install a range in any combustible cabinetry which is not in accord with the installation drawings. NOTE: 30" (76.2 cm) dimension between cooking top and wall cabinet shown on illustration does not apply to ranges with an elevated oven or microwave. The installation instructions of the elevated oven will specify the minimum acceptable dimension between the cooktop and elevated oven. The 30" (76.2 cm) dimension may be reduced to not less than 24" (61 cm) when the wall cabinets in a domestic home are protected with fireproof materials in accordance with American National Standards - National Fuel Gas Code or in mobile homes when they are protected with fireproof materials in accordance with the Federal Standard for Mobile Home Construction and Safety. To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (13 cm) beyond the bottom of the cabinets Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 1 of 2 Ref. 8101P698-60 1/27/10

  • 1
  • 2

Dual Fuel Updraft Slide-in Range
PRODUCT MODEL NUMBERS
CLEARANCE DIMENSIONS
JDS8860BD
Gas supply:
Natural gas supply line must have
a natural gas service regulator. Inlet pressure to
this appliance should be reduced to a maximum
of 14" water column (0.5 pounds per square inch
(p.s.i.) liquefied petroleum propane gas supply
line must have a L.P. gas pressure regulator. Inlet
pressure to this appliance should be reduced to a
maximum of 14" water column (0.5 p.s.i.). Inlet
pressures in excess of 0.5 p.s.i. can damage the
appliance pressure regulator and other gas
components in this appliance and can result in a
gas leak.
NOTE:
It is recommended to use a CSA certified
flexible connector no longer than 36" (91.4 cm)
with a minimum BTU/HR rating of 88,200.
A gas shutoff valve should be put in an
accessible location in the supply line ahead of the
range, for turning on and turning off gas supply.
Range is to be connected to house piping with
flexible metal connectors for gas appliances.
Connector nuts must not be connected directly to
pipe threads. The connectors must be installed
with adapters provided with the connector.
Electrical:
This range requires a single-phase
three-wire 120/240- or a 120/208-volt, 60-Hz,
AC-circuit. Wiring codes require a separate circuit
be run from the main entrance panel to the range
and that it be equipped with separate disconnect
switch and fuses, either in the main entrance
panel or in a separate switch and fuse box.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P698-60
1/27/10
Combustible
Building Walls
Combustible
Wall Cabinets
/
13" (33 cm) Max.
Depth of cabinets
above cooktop
30"
30”
(76.2 cm)
(76.
c
30”
(76.2 cm)
13"
(33 cm)
3"
(7.6 cm)
25"
(63.5cm)
18"
(45.7 cm)
3"
(7.6 cm)
18"
(45.7 cm)
30"
(76.2 cm)
Range may be installed with zero inches
clearance adjacent to (against)
combustible construction at the rear and
on the sides below the cooktop. For
complete information in regard to the
installation of wall cabinets above the
range and clearances to combustible
wall above the cooking top see the
installation drawings. For SAFETY
CONSIDERATIONS do not install a range
in any combustible cabinetry which is
not in accord with the installation
drawings.
NOTE:
30" (76.2 cm) dimension
between cooking top and wall cabinet
shown on illustration does not apply to
ranges with an elevated oven or
microwave. The installation instructions
of the elevated oven will specify the
minimum acceptable dimension between
the cooktop and elevated oven. The 30"
(76.2 cm) dimension may be reduced to
not less than 24" (61 cm) when the wall
cabinets in a domestic home are
protected with fireproof materials in
accordance with American National
Standards - National Fuel Gas Code or in
mobile homes when they are protected
with fireproof materials in accordance
with the Federal Standard for Mobile
Home Construction and Safety.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the
risk can be reduced by installing a range
hood that projects horizontally a
minimum of 5" (13 cm) beyond the
bottom of the cabinets