INSTALLATION INSTRUCTIONS Radiant Cooktop Models JEC9530 & JEC9536 403 WEST FOURTH STREET, NORTH D NEWTON, IA 50208 IMPORTANT - SAVE FOR THE LOCAL ELECTRICAL INSPECTOR'S USE IMPORTANT: Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified installer. Read safety precautions in the Use & Care Manual before using this appliance. (Dimensions shown in both inches and centimeters) JEC9530 FOUR-ELEMENT RADIANT COOKTOPS DIMENSIONS inches cm A 29-1/16 + 1/16 74.0 + 0.2 B 20-3/8 + 1/16 51.9 + 0.2 C 2-1/8 5.4 D 4-1/4 min. clear 10.8 E 29-15/16 76.0 F 21-1/2 54.6 G 3-5/8 7.6 NOTE: "DD" is clearance needed for unit depth measure down from top of countertop. Typical for all units. JEC9536 FIVE-ELEMENT RADIANT COOKTOPS DIMENSIONS inches cm A 34-9/16 + 1/16 87.9 + 0.2 B 20-3/8 + 1/16 51.9 + 0.2 C 2-1/8 5.4 D 4-1/4 min. clear 10.8 E 35-5/16 89.7 F 21-1/2 54.6 G 3-5/8 7.6 IMPORTANT CUTOUT DIMENSIONS ARE CRITICAL UNITS PROVIDED WITH 1/2² (1.3 cm) I.D. FLEXIBLE CABLE 48² (121.9 cm) LONG WITH 6² (15.2 cm) WIRE LEADS AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240/120 VOLT ELECTRICAL SERVICE). INSTRUCTIONS TO INSTALLER: S Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side walls and 3/4 inch (1.91 centimeters) from back wall. Notice To Installer: Leave these instructions with the appliance. Notice To Consumer: Retain these instructions for future reference. 8101P495-60 (01-03-00)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

INSTRUCTIONS TO
INSTALLER:
S
Side and Back Wall Clearance:
Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side
walls and 3/4 inch (1.91 centimeters) from back wall.
Notice To Installer:
Leave these instructions with the appliance.
Notice To Consumer:
Retain these instructions for future reference.
8101P495-60
(01-03-00)
DIMENSIONS
inches
cm
A
34-9/16 +
1/16
87.9 +
0.2
B
20-3/8 +
1/16
51.9 +
0.2
C
2-1/8
5.4
D
4-1/4 min. clear
10.8
E
35-5/16
89.7
F
21-1/2
54.6
G
3-5/8
7.6
INSTALLATION
INSTRUCTIONS
Radiant Cooktop
Models JEC9530 & JEC9536
403 WEST FOURTH STREET, NORTH
D
NEWTON, IA 50208
JEC9536
FIVE-ELEMENT RADIANT COOKTOPS
JEC9530
FOUR-ELEMENT RADIANT COOKTOPS
IMPORTANT
- SAVE FOR THE LOCAL ELECTRICAL INSPECTOR°S USE
IMPORTANT:
Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
(Dimensions shown in both inches and centimeters)
DIMENSIONS
inches
cm
A
29-1/16 +
1/16
74.0 +
0.2
B
20-3/8 +
1/16
51.9 +
0.2
C
2-1/8
5.4
D
4-1/4 min. clear
10.8
E
29-15/16
76.0
F
21-1/2
54.6
G
3-5/8
7.6
UNITS PROVIDED WITH 1/2
±
(1.3 cm) I.D. FLEXIBLE CABLE 48
±
(121.9 cm) LONG WITH 6
±
(15.2 cm) WIRE LEADS
AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240/120 VOLT ELECTRICAL SERVICE).
NOTE:
“D” is clearance needed for unit depth measure down from top of countertop. Typical for all units.
D
IMPORTANT
CUTOUT
DIMENSIONS ARE
CRITICAL