Jenn-Air JED3430GB Dimension Guide - Page 2
Electric Radiant Downdraft Cooktop - cooktop model
View all Jenn-Air JED3430GB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
JENN-AIR® DETAILED PLANNING DIMENSIONS 30" JX3™ ELECTRIC RADIANT DOWNDRAFT COOKTOP JED3430G - 307⁄8" x 1729⁄32" x 23" 2 of 4 OPENING/CLEARANCE DIMENSIONS A E* B F B G v C I** v H e D C FRONT VIEW MODEL # JED3430G in cm A Width of combustible area above cooking surface (min.) 30 76.2 B Width from cooktop to fixed wall or other combustible material (min.) 21⁄2 6.4 C Width to center of vent opening option (min.) 811⁄32 21.2 D Width to ouStideer edge of outlet (min.) E* Height to bCoabtitnoetm of uncovered wood or metal cabineJt above cooking surface (min.) F Height to bottom of uncovered wood or metal cabinet (min.) 10 25.4 30 76.2 18 45.7 G Height to centerKof vent opening option H Height to top edge of outlet (min.) 1313⁄16 12 35.1 30.5 I** Depth to center of vent opening option J Depth of upper cabinet (recommended) 1617⁄64 13 41.3 33.0 K Depth from cutout to wall (min.) L Width of cutout 11⁄2 287⁄8 3.8 73.3 M Depth of cutout 211⁄8 53.7 N Depth from cutout to front of countertop (min.) 2 5.1 e Recommended electrical access location v Recommended venting location - see page 3-4 for ducting information *Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. **Based on installation in a 24" (61.0 cm) deep by 341⁄2" (87.6 cm) high base cabinet with a 11⁄2" (3.8 cm) thick counter top. ELECTRICAL REQUIREMENTS 220 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required. A dedicated circuit is recommended. VENTING REQUIREMENTS This cooktop must be exhausted outdoors unless using the duct-free filter kit (JDA7000WX). Refer to kit instructions for further information. Side Cabinet J F K LOCATION REQUIREMENTS • To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout. • A minimum clearance of 6" (15.2 cm) is recommended between the side of the A cooktop and side wall for maximum ventilation performance. • A minimum and cabinet clearance of 2" (5.1 for proper cooling. cm) A 6" (is15re.2cocmmm) celnedaeradnbceetiws ereecnotmhme benlodweedrfEmo*rotor servicing access. • An under counter built-in oven cannot be installed under this cooktop. B L K M G v C I** H e N v SIDE VIEW TOP VIEW - CUTOUT C IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8989dZw117