Triple Bay Conventional Gas Grill Cooktop PRODUCT MODEL NUMBERS JGD8348CD GAS REQUIREMENTS Gas supply: The installation of this appliance must conform with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1 USA or current CAN/CGA-B149 INSTALLATION CODE. This appliance was adjusted at the factory for use with natural gas. If, at any time, this appliance is to be used with a different type of gas, all of the conversion adjustments described in the installation instructions must be made by a qualified service technician before attempting to operate the cooktop on that gas. The maximum gas supply pressure for the appliance pressure regulator supplied on this appliance is 14" W.C. The test pressure for checking this appliance pressure regulator must be at least 6" W.C. for Natural Gas, and at least 11" W.C. for LP. It is shipped from the factory set for Natural Gas at 5" W.C. Install a manual shutoff valve in an accessible location in the gas line external to this appliance for the purpose of turning on or shutting off gas to the appliance. Make the gas connection to the inlet of the appliance pressure regulator on this appliance with a 1/2" male pipe thread. Use an approved pipe joint compound resistant to the action of LP gas at pipe connections. Electrical: See page 2. PRODUCT DIMENSIONS Dimension "A" - provide 2" min. (5.1 cm) cabinet clearance to motor for cooling purpose. NOTE: Where possible, 6" (15.5 cm) is recommended for motor/blower service. Side Clearance: Grills installed near a side wall must allow a minimum clearance of 8" (20.3 cm). Access must be provided to remove and empty grease container. This appliance is designed to always be vented outdoors. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 1 of 3 Ref. 8101P620-60 09-25-08

  • 1
  • 2
  • 3

Triple Bay Conventional Gas Grill Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.
For complete details, see Installation
Instructions packed with product.
Specifications subject to change without notice.
Ref. 8101P620-60
09-25-08
Page 1 of 3
PRODUCT MODEL NUMBERS
JGD8348CD
Gas supply:
The installation of this appliance
must conform with local codes, or in the absence
of local codes, with the latest edition of the
National Fuel Gas Code ANSI Z223.1 USA or
current CAN/CGA-B149 INSTALLATION CODE.
This appliance was adjusted at the factory for use
with natural gas. If, at any time, this appliance is
to be used with a different type of gas, all of the
conversion adjustments described in the
installation instructions must be made by a
qualified service technician before attempting to
operate the cooktop on that gas.
The maximum gas supply pressure for the
appliance pressure regulator supplied on this
appliance is 14" W.C. The test pressure for
checking this appliance pressure regulator must
be at least 6" W.C. for Natural Gas, and at least
11" W.C. for LP. It is shipped from the factory set
for Natural Gas at 5" W.C.
Install a manual shutoff valve in an accessible
location in the gas line external to this appliance
for the purpose of turning on or shutting off gas
to the appliance.
Make the gas connection to the inlet of the
appliance pressure regulator on this appliance
with a 1/2" male pipe thread. Use an approved
pipe joint compound resistant to the action of LP
gas at pipe connections.
Electrical:
See page 2.
PRODUCT DIMENSIONS
Dimension “A” - provide 2" min. (5.1 cm) cabinet clearance to motor for
cooling purpose.
NOTE:
Where possible, 6" (15.5 cm) is recommended for motor/blower
service.
Side Clearance: Grills installed near a side wall must allow a minimum
clearance of 8" (20.3 cm).
Access must be provided to remove and empty grease container.
This appliance is designed to always be vented outdoors.
GAS REQUIREMENTS