Jenn-Air JGD8348CDP Installation Instruction - Page 4
Venting Requirements - 48
View all Jenn-Air JGD8348CDP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Product Dimensions 48" (121.9 cm) Cooktop A B C PO R N M L KJ D E I H F G A. 15" (38.1 cm) B. Centerline of appliance pressure regulator C. 46 118.9 cm) D. 3 8.4 cm) bottom of burner box E. ¾" (1.9 cm) F. End of burner box G. 28 72.9 cm) H. 14" (35.6 cm) I. Provide 2" (5.1 cm) min. cabinet clearance to motor for cooling purposes J. Wire cover box K. Appliance pressure regulator L. Blower M. Drain jar N. Bottom of baffle O. 3 9.7 cm) P. 5¾" (14.6 cm) R. 15 40.2 cm) min. clearance Cabinet Dimensions C K M D J E L F H G D E C AB H I N A. 1¾" (4.5 cm) min. B. 30" (76.2 cm) min. C. 48" (121.9 cm) D. 45¾" (116.2 cm) E. 46 118.9 cm) F. 18" (45.7 cm) min. clearance upper cabinet to countertop G. 22" (55.9 cm) cutout depth H. 8" (20.3 cm) min. distance on both sides of the cooktop to the side wall or other combustible material above cooking surface I. 24" (61.0 cm) cabinet depth J. 5¾" - 9" (14.6 - 22.9 cm) cabinet depth to top of countertop K. Notch to be equal on both sides L. 13" (33.0 cm) upper cabinet depth max. M. 1 2.7 cm) notch depth N. 25" (63.5 cm) countertop depth min. NOTE: Access must be provided to remove and empty grease container. 4 Cutout Dimensions B A E D C A. 9³⁄₈" (23.8 cm) B. 13 34.1 cm) C. Select appropriate duct cutout. (See ducting installation instructions.) D. 13" (33.0 cm) E. 9³⁄₈" (23.8 cm) Venting Requirements IMPORTANT: This cooktop must be exhausted outdoors. ■ Do not terminate the vent system in an attic or other enclosed area. ■ Use a Jenn-Air® vent cap. ■ Vent system must terminate to the outside. ■ Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is recommended. For best performance, do not use plastic or metal foil vent. ■ Before making cutouts, make sure there is proper clearance within the wall or floor for the exhaust vent. ■ Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. ■ The size of the vent should be uniform. ■ The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied. ■ Use vent clamps to seal all joints in the vent system. ■ Use caulking to seal exterior wall or roof opening around the cap. ■ Determine which venting method is best for your application. For Best Performance: ■ Use 26-gauge minimum galvanized or 25-gauge minimum aluminum metal vent. Poor quality pipe fittings can reduce airflow. Flexible metal vent is not recommended. NOTE: Local codes may require a heavier gauge material. ■ Metal duct may be reduced to 30-gauge galvanized steel or 26-gauge aluminized steel if allowed by local codes. This reduction is based on information in the International Residential Codes Section M1601.1 (2006 edition). ■ Do not install 2 elbows together. ■ Use no more than three 90° elbows. ■ If an elbow is used, install it as far away as possible from the hood's vent motor exhaust opening.