Jenn-Air JJW2827IL Installation Instructions - Page 3
Installation Requirements
View all Jenn-Air JJW2827IL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed ■■ Phillips screwdriver ■■ Measuring tape ■■ Hand or electric drill (for wall cabinet installations) ■■ 1" drill bit (for wall cabinet installations) ■■ Level ■■ Flat-blade screwdriver Parts Needed ■■ UL listed or CSA approved conduit connector ■■ UL listed wire connectors ■■ Warming Drawer Deflector Kit (for ovens installed above a warming drawer) Black 27" (68.6 cm) kit Stainless steel 27" (68.6 cm) kit Black 30" (76.2 cm) kit Stainless steel 30" (76.2 cm) kit To order, see the "Assistance or Service" section of the Use and Care Guide. ■■ Flush Installation Kit (for single and double installed at flush installation) Black 27" (68.6 cm) kit Stainless steel 27" (68.6 cm) kit Black 30" (76.2 cm) kit Stainless steel 30" (76.2 cm) kit To order, see the "Assistance or Service" section of the Use and Care Guide. Parts Supplied ■■ #8-14 x 1" (2.54 cm) screws - single ovens (2), double ovens (4) ■■ #8-18 x 3/8" (9.5 mm) screws - bottom vent (2) ■■ #8-18 x 1/4" (6.6 mm) screws - bottom vent trim (4) ■■ #8-18 x 3/8" (9.5 mm) screws - double oven feet (4) ■■ Bottom vent ■■ Bottom vent trim ■■ Rear feet - double oven (2) ■■ Front feet - double oven (2) ■■ Foam strip - single oven* Check local codes. Check existing electrical supply. See "Electrical Requirements." It is recommended that all electrical connections be made by a licensed, qualified electrical installer. *Foam strip not included with double oven. Location Requirements IMPORTANT: Observe all governing codes and ordinances. ■■ Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance with oven. ■■ Recessed installation area must provide complete enclosure around the recessed portion of the oven. ■■ Grounded electrical supply is required. See "Electrical Requirements" section. ■■ Electrical supply junction box should be located 3" (7.6 cm) maximum below the support surface when the oven is installed in a wall cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the right rear or left rear corner of the support surface to pass the appliance cable through to the junction box. NOTE: For undercounter installation, it is recommended that the junction box be located in the adjacent right or left cabinet. If you are installing the junction box on rear wall behind oven, it is recommended that the junction box be recessed and located in the upper center of the cabinet. ■■ Oven support surface must be solid, level, and flush with bottom of cabinet cutout. ■■ Floor must be able to support a single oven weight of 180 lbs (82 kg). ■■ Floor must be able to support a double oven weight of 357 lbs (162 kg). IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate, or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C). Undercounter Installation (with Cooktop Installed Above): Refer to the Cutout Dimensions for Ovens Installed Under Cooktop (separate sheet). See product website for list of cooktop models approved for use above select wall-oven models. 3