Jenn-Air JMW2427DS Dimension Guide - Page 3

Model

Page 3 highlights

JENN-AIR® DETAILED PLANNING DIMENSIONS 27" COMBINATION MICROWAVE/WALL OVENS JMW2427D - 27" x 433⁄4" x 255⁄16" 3 of 4 OPENING/CLEARANCE DIMENSIONS A A D C* C* B B F G H I D A B e E E e e CF F D E G MODEL #A JMW2427D in cm A Width of cabinet (min.) 27 68.6 B Width of cutout 251⁄2 64.8 C* Height of cutout (recommended) 415⁄16 104.9 D Top of cutout to bottom of upper cabinet door (min.) 21⁄4 5.7 E Bottom of cutout to topD of lower cabinet door (min.) 11⁄2 3.8 F Bottom of cutout to floor C* 4191⁄4 G Depth of cutout (min.) 24 e RecoBmmended junction box location 10.248.9 61.0 * Will fit cutout height from 41" (104.1 cm) to 411⁄2" (105.6 cm). ELECTRICAL REQUIREMENTS 240 volt, 40-amp fused, grounded circuit is required. A dedicated circuit is required. The length of conduit provided is for serviceability. Do not cut the conduit. The junction box should be located 3" (7.6 cm) maximum below the support surfEace. Drill a 1" (2.5 cm) minimum diameter hole in the right rear or left rear corner of the support surface for access to the junction box. G e F FRONT VIEW SIDE VIEW Power Supply Location BACK VIEW IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8328AdZw615

  • 1
  • 2
  • 3
  • 4

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
3 of 4
8328AdZw615
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
27" COMBINATION MICROWAVE/WALL OVENS
JMW2427D – 27" x 43
3
4
" x 25
5
16
"
MODEL #
JMW2427D
in
cm
A
Width of cabinet (min.)
27
68.6
B
Width of cutout
25
1
2
64.8
C*
Height of cutout
(recommended)
41
5
16
104.9
D
Top of cutout to bottom
of upper cabinet door (min.)
2
1
4
5.7
E
Bottom of cutout to top
of lower cabinet door (min.)
1
1
2
3.8
F
Bottom of cutout to floor
4-
19
1
4
10.2-
48.9
G
Depth of cutout (min.)
24
61.0
e
Recommended junction box location
* Will fit cutout height from 41" (104.1 cm) to 41
1
2
" (105.6 cm).
Power Supply
Location
A
B
C*
e
e
D
E
F
G
FRONT VIEW
SIDE VIEW
BACK VIEW
OPENING/CLEARANCE DIMENSIONS
ELECTRICAL REQUIREMENTS
240 volt, 40-amp fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6 cm)
maximum below the support surface. Drill a 1" (2.5 cm) minimum
diameter hole in the right rear or left rear corner of the support