Jenn-Air JUB24FLECX Dimension Guide - Page 3

Front View, Side View, Back View

Page 3 highlights

JENN-AIR® DETAILED PLANNING DIMENSIONS UNDER COUNTER BEVERAGE CENTERS JUB24FRERS, JUB24FLERS - 237⁄8" x 343⁄8" x 26" (including handle) JUB24FRECX, JUB24FLECX - 237⁄8" x 343⁄8" x 237⁄8" 3 of 3 OPENING/CLEARANCE DIMENSIONS B FRONT VIEW C A B Wall Wall MODEL # D A Width (min.) B Minimum width from hinged side of beverage center to fixed wall - door open 90° C Height (min.) Floor D Depth (min.) JUB24FRERS JUB24FLERS JUB24FRECX JUB24FLECX in cm 24 61.0 15⁄8 4.0 343⁄8 24 87.3 61.0 VENTILATION REQUIREMENTS For proper ventilation, allow 1⁄4" (0.6 cm) space on the top and each side. ELECTRICAL REQUIREMENTS 115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is required. A dedicated circuit is recommended. Use an outlet that cannot be turned off by a switch. Minimum length of the power cord is 63" (160.0 cm). Do not use an extension cord. D Floor SIDE VIEW BACK VIEW IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8281AdZw1214

  • 1
  • 2
  • 3

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
3 of 3
8281AdZw1214
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation or Use & Care Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
UNDER COUNTER BEVERAGE CENTERS
JUB24FRERS, JUB24FLERS – 23
7
8
" x 34
3
8
" x 26" (including handle)
JUB24FRECX, JUB24FLECX – 23
7
8
" x 34
3
8
" x 23
7
8
"
MODEL #
JUB24FRERS
JUB24FLERS
JUB24FRECX
JUB24FLECX
in
cm
A
Width (min.)
24
61.0
B
Minimum width from hinged side of beverage
center to fixed wall – door open 90°
1
5
8
4.0
C
Height (min.)
34
3
8
87.3
D
Depth (min.)
24
61.0
VENTILATION REQUIREMENTS
For proper ventilation, allow
1
4
" (0.6 cm) space on the top and each side.
ELECTRICAL REQUIREMENTS
115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is required.
A dedicated circuit is recommended. Use an outlet that cannot be turned off
by a switch. Minimum length of the power cord is 63" (160.0 cm). Do not
use an extension cord.
C
A
B
B
FRONT VIEW
SIDE VIEW
Floor
Wall
D
BACK VIEW
OPENING/CLEARANCE DIMENSIONS