Jenn-Air JVD0303GS Dimension Guide - Page 2

Modular Downdraft Vent

Page 2 highlights

JENN-AIR® DETAILED PLANNING DIMENSIONS 4" MODULAR DOWNDRAFT VENT JVD0303GS - 37⁄8" x 21" 2 of 2 OPENING/CLEARANCE DIMENSIONS A D* E B B F e C FRONT VIEW Side Cabinet G H MODEL # JVD0303GS in cm A Width of combustible area above cooking surface (min.) 187⁄8 47.9 B Width from vent module to fixed wall or other combSuidestible material (min.) 6 15.2 Cabinet C Width to outer edge of outlet (max.) 6 15.2 D* Height to bottom of uncovered wood or metal cabineGt above cooking surface (min.) 30 76.2 E Height to bottom of uncovered wood or metal cabinet (mHin.) 18 45.7 F Height to top edge of outlet (min.) 10 25.4 G Depth of upper cabinet 13 33.0 H Depth from cutout to wall (min.) 25 ⁄16 5.9 I Width of cutout with one module 183⁄16 46.2 J Depth of cutout (recommended) 203⁄8 51.8 K Depth from cutout to front of countertop 25⁄16 5.9 e Recommended electrical access location *Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. If installing a hood or microwave hood combination above the cooktop, follow the hood or microwave hood combination instructions for dimensional clearances above the cooking surface. ELECTRICAL REQUIREMENTS A 120 Volt, 60 Hz, AC only 15-amp fused, grounded electrical circuit is required. A dedicated circuit is required. A grounded 3-prong outlet should be located in the back of the cabinet. Do not use an extension cord. LOCATION REQUIREMENTS • T o ensure cooktop base clearance, cabinet side walls need to be wider than the cutout. A I H J D* B F e C SIDE VIEW K TOP VIEW IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8998AdZw917

  • 1
  • 2

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
2 of 2
8998AdZw917
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
4" MODULAR DOWNDRAFT VENT
JVD0303GS – 3
7
8
" x 21"
OPENING/CLEARANCE DIMENSIONS
I
K
J
H
D*
E
A
B
B
C
e
F
G
Side
Cabinet
H
MODEL #
JVD0303GS
in
cm
A
Width of combustible area above
cooking surface (min.)
18
7
8
47.9
B
Width from vent module to fixed wall or
other combustible material (min.)
6
15.2
C
Width to outer edge of outlet (max.)
6
15.2
D*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
30
76.2
E
Height to bottom of uncovered wood or
metal cabinet (min.)
18
45.7
F
Height to top edge of outlet (min.)
10
25.4
G
Depth of upper cabinet
13
33.0
H
Depth from cutout to wall (min.)
2
5
16
5.9
I
Width of cutout with one module
18
3
16
46.2
J
Depth of cutout (recommended)
20
3
8
51.8
K
Depth from cutout to front of countertop
2
5
16
5.9
e
Recommended electrical access location
*Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than
1
4
" (0.6 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood or microwave hood combination above the cooktop,
follow the hood or microwave hood combination instructions for
dimensional clearances above the cooking surface.
FRONT VIEW
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz, AC only 15-amp fused, grounded electrical circuit is
required. A dedicated circuit is required.
A grounded 3-prong outlet should be located in the back of the cabinet.
Do not use an extension cord.
LOCATION REQUIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider
than the cutout.
TOP VIEW
SIDE VIEW