Jenn-Air JXD7030Y Dimension Guide - Page 2

Telescoping Downdraft Ventilation - jxd7030ys

Page 2 highlights

Countertop JENN-AIR® DETAILEDJ and Backsplash PLANNING DIMENSIONS 36"/30" TELESCO Vent Box PING DOWNDRAFT VENTILATION JXD7036YS - 36" x 421⁄8" x 121⁄8" JXD7030YS - 30" x 421⁄8" x 121⁄8" OPENING/CLEARANCE DIMENSIONS 2 of 2 D AK A G F Centerline of Cooktop FRONT VIEW B v LOCATIONC REQUIREEMENTS Bull-nosed front evdge countertops are not recommended. Some cooktop and vent combinations may require a countertop deeper than 25" (63.5 cm). ELECTRICAL REQUIREMENTS 120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required. VENTING REQUIREMENTS The vent is factory set for a 31⁄4" x 10" (8.3 cm x 25.4 cm) rectangular or a 6" (15.2 cm) diameter vent system venting through the wall or floor. Do not terminate the vent in an attic or other enclosed area. Cooktop MODEL # D C E v A Width of cutout B Depth from center of vent cutout to back wall - floor vent option C Height from center of vent cutout to countertop - side wall vent option D Depth from back wall to vent box cutout (min.) E Depth from center of vent cutout to back wall - side wall vent option F Recessed cooktop to countertop cutout SIDE VIEW CUTOUT DIMENSIONS G Countertop cutout to backsplash (min.) H* Rear overhang of cooktop I Top trim to backsplash (min.) J Vent box to back of cabinet (min.) K Depth of backsplash (max.) e Recommended junction box location v Recommended venting location F H* Cooktop F G H* I G *Cooktop overhang will vary depending on model. K I A G KF Countertop A J and Backsplash G F Vent BoJx Countertop and Backsplash JXD7036YS in cm 331⁄2 85.9 10 25.4 JXD7030YS in cm 271⁄2 69.9 10 25.4 213⁄8 1⁄2 10 H + 17⁄8 1⁄2 - 1⁄4 1⁄2 3⁄4 54.1 1.3 25.4 H + 4.6 1.3 - 0.6 1.3 1.9 213⁄8 1⁄2 10 H + 17⁄8 1⁄2 - 1⁄4 1⁄2 3⁄4 54.1 1.3 25.4 H + 4.6 1.3 - 0.6 1.3 1.9 31⁄4" x 10" (8.3 cm x 25.4 cm) rectangular or 6" (15.2 cm) diameter cutout Vent Box SIDE VIEW TOP VIEW - CUTOUT IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. D 8562BdZw815

  • 1
  • 2

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
JENN-AIR
®
DETAILED PLANNING DIMENSIONS
2 of 2
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
8562BdZw815
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
MODEL #
JXD7036YS
JXD7030YS
in
cm
in
cm
A
Width of cutout
33
1
2
85.9
27
1
2
69.9
B
Depth from center of vent cutout to back wall –
floor vent option
10
25.4
10
25.4
C
Height from center of vent cutout to
countertop – side wall vent option
21
3
8
54.1
21
3
8
54.1
D
Depth from back wall to vent box cutout (min.)
1
2
1.3
1
2
1.3
E
Depth from center of vent cutout to back wall –
side wall vent option
10
25.4
10
25.4
F
Recessed cooktop to countertop cutout
H
+
1
7
8
H
+
4.6
H
+
1
7
8
H
+
4.6
G
Countertop cutout to backsplash (min.)
1
2
1.3
1
2
1.3
H*
Rear overhang of cooktop
I
Top trim to backsplash (min.)
1
4
0.6
1
4
0.6
J
Vent box to back of cabinet (min.)
1
2
1.3
1
2
1.3
K
Depth of backsplash (max.)
3
4
1.9
3
4
1.9
e
Recommended junction box location
v
Recommended venting location
3
1
4
" x 10" (8.3 cm x 25.4 cm)
rectangular or 6" (15.2 cm)
diameter cutout
*Cooktop overhang will vary depending on model.
SIDE VIEW
CUTOUT DIMENSIONS
SIDE VIEW
36"/30" TELESCOPING DOWNDRAFT VENTILATION
JXD7036YS – 36" x 42
1
8
" x 12
1
8
"
JXD7030YS – 30" x 42
1
8
" x 12
1
8
"
Cooktop
Countertop
and Backsplash
Vent Box
F
G
I
J
H*
v
C
E
D
A
B
Centerline
of Cooktop
v
LOCATION REQUIREMENTS
Bull-nosed front edge countertops are not recommended. Some cooktop
and vent combinations may require a countertop deeper than 25" (63.5 cm).
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The vent is factory set for a 3
1
4
" x 10" (8.3 cm x 25.4 cm) rectangular
or a 6" (15.2 cm) diameter vent system venting through the wall or floor.
Do not terminate the vent in an attic or other enclosed area.
A
F
G
K
TOP VIEW – CUTOUT