Connect Vent System 1. Install vent system. 2. Push duct over the exhaust outlet. Seal all connections with vent clamps. Non-Vented (recirculating) Installation 1. Attach the air deflector to the upper horizontal support using 4 mounting screws. 3. Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief. A B A B A. Deflector B. Mounting screws 2. Measure the length of 8" (20.3 cm) duct needed to connect the transition to the deflector. NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum. 3. Install vent between the transition and the deflector. NOTE: To make vent installation easier, temporarily remove the deflector from the chimney support bracket and replace after vent section is in place. 4. Seal all connections with vent clamps. Make Electrical Connection WARNING A. Knockout B. Terminal box cover 4. Run home power supply cable through strain relief, into terminal box. A B C D Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove terminal box cover. E F A. Home power supply cable B. UL listed or CSA approved strain relief C. Black wires D. UL listed wire connectors E. White wires F. Green (or bare) and yellow-green ground wires 5. Use UL listed wire connectors and connect black wires (C) together. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

9
Connect Vent System
1.
Install vent system.
2.
Push duct over the exhaust outlet. Seal all connections with
vent clamps.
Non-Vented (recirculating) Installation
1.
Attach the air deflector to the upper horizontal support using
4 mounting screws.
2.
Measure the length of 8" (20.3 cm) duct needed to connect
the transition to the deflector.
NOTE:
Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3.
Install vent between the transition and the deflector.
NOTE:
To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4.
Seal all connections with vent clamps.
Make Electrical Connection
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install a
UL listed or CSA approved
¹⁄₂
" strain relief.
4.
Run home power supply cable through strain relief, into
terminal box.
5.
Use UL listed wire connectors and connect black wires (C)
together.
A. Deflector
B. Mounting screws
B
A
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A. Knockout
B. Terminal box cover
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires