Jenn-Air UXT5536AAS Dimension Guide - Page 2

cm or Larger Round Vent System - whirlpool

Page 2 highlights

Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System Vent Piece Round 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) 6" (15.2 cm) or larger wall cap 0.0 ft (0.0 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) or larger 4.5 ft (1.4 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) or larger 90° elbow 5.0 ft (1.5 m) Example vent system 90˚ elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 1 - wall cap 8 ft (2.4 m) straight Length of 7" (17.8 cm) system = 50 ft (15.2 m) = 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m) = 13.0 ft (3.9 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece Round 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 90° elbow 5.0 ft (1.5 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) flat elbow 12.0 ft (3.7 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) wall cap 0.0 ft (0.0 m) Example vent system 3¹⁄₄" x 10" (8.3 x 25.4 cm) elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 8 ft (2.4 m) straight 1 - wall cap Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) system = 35 ft (10.7 m) = 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m) = 13.0 ft (3.9 m) Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 2 of 2 Ref. W10274302B 10/22/09

  • 1
  • 2

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274302B
10/22/09
Page 2 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System
Vent Piece
Round
45
°
elbow
2.5 ft
(0.8 m)
90
°
elbow
5.0 ft
(1.5 m)
6" (15.2 cm) or larger
0.0 ft
wall cap
(0.0 m)
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
4.5 ft
to 6" (15.2 cm) or larger
(1.4 m)
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
5.0 ft
to 6" (15.2 cm) or larger
(1.5 m)
90
°
elbow
Example vent system
Maximum Recommended Length
= 50 ft (15.2 m)
1 - 90
°
elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of 7" (17.8 cm) system
= 13.0 ft (3.9 m)
Wall cap
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
Round
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
5.0 ft
90
°
elbow
(1.5 m)
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
12.0 ft
flat elbow
(3.7 m)
3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
0.0 ft
wall cap
(0.0 m)
Example vent system
Maximum Recommended Length
= 35 ft (10.7 m)
1 - 90
°
elbow
= 5.0 ft (1.5 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
1 - wall cap
= 0.0 ft (0.0 m)
Length of 3
¹⁄₄
" x 10" (8.3 cm x 25.4 cm)
= 13.0 ft (3.9 m)
system
Wall cap
3
¹⁄₄
" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)