Kenmore 7756 Installation Instructions - Page 6
connect, to range., Burner, Grates
View all Kenmore 7756 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
5. Read these electrical connection details first then connect electricity to range. Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord. Electric Requirements: A dedicated, properly grounded and polarized branch circuit protected by a 15 amp. circuit breaker or time delay fuse. See serial plate for proper voltage. Extension Cord Precautions: Because of potential safety hazards under certain conditions, we strongly recommend against the use of any extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than the branch circuit rating. Such extension cords are obtainable through your local service organization. Grounding instructions The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance, The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and polarized, 6. Assembly of the Burner Caps and Burner Grates: It is very important to makes sure that all of the Surface Burner Caps and Surface Burner Grates are installed correctly and in the correct locations, Please Note: The burner heads are secured cooktop. THE COOKTOP IS NOT REMOVABLE. attempt to remove or lift the cooktop. to the Do not PLEASE READ CAREFULLY! For personal safety, this product must be properly grounded. Preferred Method DO Not, Under _'_ Any Circumstances, I Cut, Remove, | or Bypass the J REMEMBER -- DO NOT ALLOW SPILLS, FOOD, CLEANING AGENTS OR ANY OTHER MATERIAL TO ENTER THE GAS ORIFICE HOLDER OPENING. Always keep the Burner Caps and Burner Heads in place whenever the surface burners are in use. Grounding Type Wall Receptacle rounding Prong..,,/ Power Supply _1_ Cord with _ 3=Prong _ Grounding Plug Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle. DO NOT, UNDERANYCIRCUMSTANCES, CUTOR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.