Cabinet Side View A B E C D A. 23¹⁄₄" (59.1 cm) min. cutout depth B. 23" (58.4 cm) recessed oven depth C. Oven front D. Recessed oven E. Cabinet Electrical Requirements GROUNDING INSTRUCTIONS For a permanently connected microwave oven: The microwave oven must be connected to a grounded, metallic, permanent wiring system, or an equipment grounding conductor should be run with the circuit conductors and connected to the equipment grounding terminal or lead on the microwave oven. SAVE THESE INSTRUCTIONS If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes. Check with a qualified electrical installer if you are not sure the microwave oven is properly grounded. This microwave oven must be connected to a grounded metal, permanent wiring system. Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 Electrical Connection To properly install your microwave oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■ Microwave oven must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located on the right-hand microwave oven frame. A A. Model/serial number plate ■ When a 4-wire, single phase 208/220 volt, 60 Hz, AC only electrical supply is required, a 20-amp maximum circuit protection is required, fused on both sides of the line. ■ A time-delay fuse or circuit breaker is recommended. ■ Connect directly to the fused disconnect (or circuit breaker box) through flexible, nonmetallic sheathed, copper cable (with grounding wire). See "Make Electrical Connection" section. ■ Flexible cable from the microwave oven should be connected directly to the junction box. ■ Do not cut the conduit. The length of conduit provided is for serviceability of the microwave oven. ■ A UL listed or CSA approved conduit connector must be provided. ■ If the house has aluminum wiring, follow the procedure below: 1. Connect a section of solid copper wire to the pigtail leads. 2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices. 4