KitchenAid KDFE104DSS Dimension Guide - Page 1

KitchenAid KDFE104DSS Manual

Page 1 highlights

Undercounter Dishwasher PRODUCT MODEL NUMBERS KDFE104D KDFE304D KDTE104D KDTE204D KDTE404D Electrical Requirements: 120-volt, 60 Hz, AC-only, 15- or 20 amp fused electrical supply. Copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended. Water Supply Requirements: A hot water line with 20 to 120 psi (138 to 862 kPa) water pressure. Water temperature must be 120°F (49°C) water at dishwasher. Use ³⁄₈" O.D. copper tubing with compression fitting or flexible braided supply line (¹⁄₂" minimum plastic tubing is not recommended). Use a 90° elbow with ³⁄₄" N.P.T. external pipe threads on one end. Do not solder within 6" (15.2 cm) from water inlet valve. Drain Requirements: A new drain hose is supplied with your dishwasher. If this is not long enough, use a new drain hose with a maximum length of 12 ft (3.7 m) (Part Number 3385556) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the 1" (2.5 cm) drain connector of the dishwasher. Make sure to connect the drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20" (50.8 cm) minimum above the floor. It is recommended that the drain hose either be air gap looped up and securely fastened to the underside of the counter, or be connected to an air gap. Make sure to use an air gap if the drain hose is connected to house plumbing lower than 20" (50.8 cm) above subfloor or floor. Use ¹⁄₂" (1.3 cm) minimum I.D. drain line fittings. If required, the air gap should be installed in accordance with the air gap installation instructions. When you connect the air gap, a rubber hose (not provided) will be needed to connect to the waste tee or disposer inlet. PRODUCT DIMENSIONS 24¹⁄₂" (62.2 cm) B 23⁷⁄₈" (60.6 cm) 27¹⁄₂" (68.8 cm) C 30" (76.2 cm) 33¹⁄₂" (85.1 cm) min. with wheels removed 3¹⁄₂" - 4¹⁄₄" (8.8 cm - 10.6 cm) For 4" (10 cm) toe kick, height of cabinet opening is 34¹⁄₂" (86.3 cm). 3³⁄₄" (9.4 cm) 21" (53.3 cm) A. Insulation may be compressed (not used on all models). B. For panel ready models, dishwasher depth is 24" (60 cm) not including the ³⁄₄" (1.9 cm) custom door panel. C. For Pro Line® handle, depth is 28" (70 cm). ³⁄₄" (1.9 cm) A Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 1 of 2 W10579129-D-KA 12/20/13

  • 1
  • 2

PRODUCT DIMENSIONS
Undercounter Dishwasher
PRODUCT MODEL NUMBERS
KDFE104D
KDFE304D
KDTE104D
KDTE204D
KDTE404D
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
W10579129-D-KA
12/20/13
24
¹⁄₂
"
(62.2 cm)
B
23
⁷⁄₈
"
(60.6 cm)
27
¹⁄₂
"
(68.8 cm)
C
B. For panel ready models, dishwasher
depth is 24" (60 cm) not including the
³⁄₄
" (1.9 cm) custom door panel.
C. For
Pro Line
handle, depth is
28" (70 cm).
®
³⁄₄
"
(1.9 cm)
A
A. Insulation may be compressed
(not used on all models).
33
¹⁄₂
"
(85.1 cm)
min. with
wheels
removed
3
¹⁄₂
" -
4
¹⁄₄
"
(8.8 cm - 10.6 cm)
For 4" (10 cm) toe
kick, height of cabinet
opening is 34
¹⁄₂
" (86.3 cm).
3
³⁄₄
"
(9.4 cm)
21
"
(53.3 cm)
30"
(76.2 cm)
Page 1 of 2
Electrical Requirements:
120-volt, 60 Hz, AC-only, 15- or
20 amp fused electrical supply. Copper wire only. A
time-delay fuse or circuit breaker and separate circuit is
recommended.
Water Supply Requirements:
A hot water line with 20 to
120 psi (138 to 862 kPa) water pressure. Water
temperature must be 120°F (49°C) water at dishwasher.
Use
³⁄₈
" O.D. copper tubing with compression fitting or
flexible braided supply line (
¹⁄₂
" minimum plastic tubing is
not recommended). Use a 90° elbow with
³⁄₄
" N.P.T. external
pipe threads on one end. Do not solder within 6" (15.2 cm)
from water inlet valve.
Drain Requirements:
A new drain hose is supplied with
your dishwasher. If this is not long enough, use a new drain
hose with a maximum length of 12 ft (3.7 m) (Part Number
3385556) that meets all current AHAM/IAPMO test
standards, is resistant to heat and detergent, and fits the 1"
(2.5 cm) drain connector of the dishwasher.
Make sure to connect the drain hose to waste tee or
disposer inlet above drain trap in house plumbing and 20"
(50.8 cm) minimum above the floor. It is recommended
that the drain hose either be
looped up and securely
fastened to the underside of
the counter, or be connected
to an air gap.
Make sure to use an air gap
if the drain hose is
connected to house
plumbing lower than 20"
(50.8 cm) above subfloor or
floor.
Use
¹⁄₂
" (1.3 cm) minimum I.D. drain line fittings.
If required, the air gap should be installed in accordance
with the air gap installation instructions. When you connect
the air gap, a rubber hose (not provided) will be needed to
connect to the waste tee or disposer inlet.
air gap