KitchenAid KDFE104KBL Owners Manual - Page 19

Connect ground wire, Connect remaining wires, Wiring configuration

Page 19 highlights

WARNING Wiring configuration Electrical Shock Hazard Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 21. Connect ground wire Ground connector screw 23. Secure cord or wire in strain relief Terminal box cover Ground wire Washer Ground screw Route power cord through strain relief in the back of the terminal box. Remove the ground connector screw on the raised floor inside the box and place it through the ring terminal of the green ground wire of power cord. If wire has no ring terminal, bend a loop in the end of the wire. Reattach and tighten the ground connector screw to the raised floor of the box. 22. Connect remaining wires White wire White wire Ground wire Tighten strain relief screws to secure cord. 24. Reinstall terminal box cover and wires Black wire Black wire To connect wires with ring terminals, remove the screws from the terminal block, place the screw through the ring terminals, and reattach screws back into the terminal block. To connect wires without ring terminals, remove the screws from the terminal block. Bend a loop in the end of the wires. Push the screws through the loop. Return the screws to the terminal block. Tighten the screws. NOTE: Pre-tinned wires should not be used when connecting to the terminal block. Place wires inside terminal box. Replace the cover by inserting the hooks of the terminal cover into the slots in the floor of the terminal box and sliding the cover tight against the back wall where wires come in. Make sure wires are tucked inside the box and not pinched by the cover. Put the terminal box back on the crossbar and push to the right so terminal box snaps into the plastic side member. NOTES: ■ Do not plug cord into an outlet until instructed to do so. ■ Once the terminal box has been remounted on the dishwasher, tuck any excess length or slack over nearby components to help keep them off the floor. ■ Route cord out the rear of the dishwasher so that it does not touch dishwasher motor or lower part of dishwasher tub. ■ A maximum of 2 power cord supply conductors (12 AWG largest size) plus 1 grounding conductor are permitted in the terminal box. IMPORTANT: No additional connections other than dishwasher power connection are to be made inside the dishwasher terminal box. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

19
Route power cord through strain relief in the back of the terminal
box. Remove the ground connector screw on the raised floor
inside the box and place it through the ring terminal of the green
ground wire of power cord. If wire has no ring terminal, bend a
loop in the end of the wire. Reattach and tighten the ground
connector screw to the raised floor of the box.
To connect wires with ring terminals, remove the screws from the
terminal block, place the screw through the ring terminals, and
reattach screws back into the terminal block.
To connect wires without ring terminals, remove the screws from
the terminal block. Bend a loop in the end of the wires. Push the
screws through the loop. Return the screws to the terminal block.
Tighten the screws.
NOTE:
Pre-tinned wires should not be used when connecting to
the terminal block.
Tighten strain relief screws to secure cord.
Place wires inside terminal box. Replace the cover by inserting
the hooks of the terminal cover into the slots in the floor of the
terminal box and sliding the cover tight against the back wall
where wires come in. Make sure wires are tucked inside the box
and not pinched by the cover.
Put the terminal box back on the crossbar and push to the right
so terminal box snaps into the plastic side member.
NOTES:
Do not plug cord into an outlet until instructed to do so.
Once the terminal box has been remounted on the dishwasher,
tuck any excess length or slack over nearby components to
help keep them off the floor.
Route cord out the rear of the dishwasher so that it does not
touch dishwasher motor or lower part of dishwasher tub.
A maximum of 2 power cord supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.
IMPORTANT:
No additional connections other than dishwasher
power connection are to be made inside the dishwasher terminal
box.
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
21.
Connect ground wire
22.
Connect remaining wires
Wiring configuration
23.
Secure cord or wire in strain relief
Terminal
box cover
24.
Reinstall terminal box cover and wires
Ground
wire
Ground
screw
Washer
Ground connector
screw
White wire
White wire
Black wire
Black wire
Ground wire