KitchenAid KDSS907SSS Installation Guide - Page 19

Gas Conversions - troubleshoot

Page 19 highlights

Replace Oven Racks and Warming Drawer Replace oven racks in oven cavity. Replace warming drawer or storage drawer. To Replace Warming Drawer: 1. Align the drawer glides with the receiving guides. 2. Push drawer in all the way. 3. Gently open and close the drawer to ensure it is seated properly on the slides. Complete Installation 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. 2. Check that you have all of your tools. 3. Dispose of/recycle all packaging materials. 4. Check that range level. See the "Level Range" section. 5. Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material. Dry thoroughly with a soft cloth. For more information, see the "Range Care" section of the Use and Care Guide. 6. Read the "Range Use" section in the Use and Care Guide. 7. Plug power cord into appropriate outlet. Slide range into its final location. Check that the flexible conduit or power supply cord are not bent. 8. Turn on surface burners and oven. See the Use and Care Guide for specific instruction on range operation. If range does not operate, check the following: ■ Household fuse is intact and tight, or circuit breaker has not tripped. ■ Range is plugged into an outlet. ■ Electrical supply is connected. ■ See the "Troubleshooting" section in the Use and Care Guide. 9. When the range has been on for 5 minutes, check for heat. If the range is cold, turn off the range and check that the gas supply line shutoff valve is open. ■ If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as outlined above. ■ If the gas supply line shutoff valve is open, close it, and contact a qualified technician. If you need Assistance or Service: Please reference the "Assistance or Service" section of the Use and Care Guide or contact the dealer from whom you purchased your range. GAS CONVERSIONS Gas conversions from Natural gas to LP gas; or from LP gas to Natural gas must be done by a qualified installer. LP Gas Conversion WARNING WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. To Convert Gas Pressure Regulator 1. Turn manual shutoff valve to the "closed" position. B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

19
Replace Oven Racks and Warming Drawer
Replace oven racks in oven cavity. Replace warming drawer or
storage drawer.
To Replace Warming Drawer:
1.
Align the drawer glides with the receiving guides.
2.
Push drawer in all the way.
3.
Gently open and close the drawer to ensure it is seated
properly on the slides.
Complete Installation
1.
Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2.
Check that you have all of your tools.
3.
Dispose of/recycle all packaging materials.
4.
Check that range level. See the “Level Range” section.
5.
Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, see
the “Range Care” section of the Use and Care Guide.
6.
Read the “Range Use” section in the Use and Care Guide.
7.
Plug power cord into appropriate outlet. Slide range into its
final location. Check that the flexible conduit or power supply
cord are not bent.
8.
Turn on surface burners and oven. See the Use and Care
Guide for specific instruction on range operation.
If range does not operate, check the following:
Household fuse is intact and tight, or circuit breaker has not
tripped.
Range is plugged into an outlet.
Electrical supply is connected.
See the “Troubleshooting” section in the Use and Care Guide.
9.
When the range has been on for 5 minutes, check for heat. If
the range is cold, turn off the range and check that the gas
supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, close it, and
contact a qualified technician.
If you need Assistance or Service:
Please reference the “Assistance or Service” section of the
Use and Care Guide or contact the dealer from whom you
purchased your range.
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas; or from LP gas to
Natural gas must be done by a qualified installer.
LP Gas Conversion
To Convert Gas Pressure Regulator
1.
Turn manual shutoff valve to the “closed” position.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C