KitchenAid KGRS505XSS Installation Guide - Page 11

Gas Conversions - gas range

Page 11 highlights

GAS CONVERSIONS Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer. To Convert Gas Pressure Regulator WARNING 1. Locate gas pressure regulator at the rear of the range. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. LP Gas Conversion WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. 1. Turn manual shutoff valve to the closed position. 2. Unplug range or disconnect power. B A C A. To range B. Shutoff valve (closed position) C. Gas supply line A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 2. Unscrew the hex-shaped regulator cap from the regulator and remove the regulator pin. A B A. Regulator pin B. Regulator cap 3. Flip the regulator pin over and snap pin firmly into place. A B A. Natural gas position B. LP gas position 4. Screw the hex-shaped regulator cap securely back into place. Do not overtighten. To Convert Oven Bake Burners To Convert Lower Oven Bake Burner: 1. Remove oven racks from inside the oven cavity. 2. Remove oven door. See "Oven Door" section in the Use and Care Guide for oven door removal instructions. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

11
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
LP Gas Conversion
1.
Turn manual shutoff valve to the closed position.
2.
Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1.
Locate gas pressure regulator at the rear of the range.
IMPORTANT:
Do not remove the gas pressure regulator.
2.
Unscrew the hex-shaped regulator cap from the regulator
and remove the regulator pin.
3.
Flip the regulator pin over and snap pin firmly into place.
4.
Screw the hex-shaped regulator cap securely back into
place. Do not overtighten.
To Convert Oven Bake Burners
To Convert Lower Oven Bake Burner:
1.
Remove oven racks from inside the oven cavity.
2.
Remove oven door. See “Oven Door” section in the Use and
Care Guide for oven door removal instructions.
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A. Gas pressure regulator
A. Regulator pin
B. Regulator cap
A. Natural gas position
B. LP gas position
A
A
B
A
B