Venting Design Specifications
View all KitchenAid KMLS311HSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and builder/ contractor reference only. NOTES: A ■■ Vent materials needed for installation are not provided with microwave hood combination. ■■ We do not recommend using a flexible metal vent. B ■■ To avoid possible product damage, be sure to vent air C D outside, unless using recirculation installation. Do not vent exhaust air into concealed spaces, such as spaces within walls or ceilings, attics, crawl spaces, or garages. E For optimal venting installation, we recommend: ■■ Using roof or wall caps that have back draft dampers 3" (7.6 cm) F ■■ Using a rigid metal vent ■■ Using the most direct route by minimizing the length of the vent and number of elbows to provide efficient performance ■■ Using uniformly sized vents ■■ Using duct tape to seal all joints in the vent system ■■ Using caulking compound to seal exterior wall or roof opening around cap A. Roof cap B. 6" (15.2 cm) min. diameter round vent C. Elbow (for wall venting only) D. Wall cap E. 3¹⁄4" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm) rectangular to round transition piece F. Vent extension piece, at least 3" (7.6 cm) high ■■ Not installing 2 elbows together for optimal hood performance If venting through the wall, be sure that there is proper clearance within the wall for the damper to open fully. If venting through the roof, and rectangular-to-round transition is used, be sure there are at least 3" (7.6 cm) of clearance between the top of the microwave oven and the transition piece. See "Rectangular-to-Round Transition" illustration. Recommended Vent Length A 3¹⁄4" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used. The total length of the vent system including straight vent, elbow(s), transitions, and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. See the "Recommended Standard Fittings" section for equivalent lengths. For best performance, use no more than three 90° elbows. To calculate the length of the system you need, add the equivalent lengths of each vent piece used in the system. See the following examples. 3¹⁄4" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total. Roof venting Roof cap A B 6 ft (1.8 m) 2 ft (0.6 m) C A. One 3¹⁄4" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) B. 1 wall cap = 40 ft (12.2 m) C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m) Wall venting Wall cap Rectangular-to-Round Transition NOTE: The minimum 3" (7.6 cm) clearance must exist between the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully. 11