GP 20 NVM Reset 1. Purpose The NVM Reset procedure is used to recover booklet quality base NVM values for side guides, staple stop gate, fold stop gate, staple position, back jogger and trim knife zero. The NVM Reset procedure is used after updating software, replacing the PCB Controller, PCB A, PCB Printer interface, PCB E (BM) or F (RCT), or when a part affecting the booklet quality has been replaced. The NVM reset procedure can also be initiated to resolve minor logic problems. 2. Procedure General procedure to perform NVM reset is described below. Depending on circumstances, exact procedure to retieve NVM values may vary, see flowcharts further below. NOTE: All data in the EEPROM will be cleared including jobs, jam history etc. The only data not cleared are the Staple, Fold, Trim, Cover Feed, Rotator, Crease and Bleed Trimmer counters. 1. Enter the service menu (GP 1). 2. Select target (module) BM. 3. Select item [NVM]. 4. Record NVM values: BM: Index 2-7 and 11. 5. Press [Home] to reach Target selection menu. 6. Select target (module) [RCT]. 7. Select item [NVM]. 8. Record NVM values: RCT: Index 2-4. 9. Press [Go back] to reach RCT Service Components menu. 10. Select item [Reset NVM]. Follow on screen instruction. 11. Press [Reset]. Read/follow on screen instructions. Press [Go back] to reach RCT Service Components menu. 12. Select item [NVM]. 13. Re-enter NVM values RCT: Index 2-4 recorded in step 8. 14. Press [Home] to reach Target selection menu. 15. Select target (module) [BM]. 16. Select item [Reset NVM]. Follow on screen instruction. 17. Press [Reset]. Read/follow on screen instructions. Press [Go back] to reach BM Service Components menu. 18. Select item [NVM]. 19. Re-enter NVM values BM: Index 2-7 and 11 recorded in step 4. 20. Press [Go back] to reach BM Service components menu. 21. Select [Printer] (GP 8). 22. If present, enable Cover Feeder Module (GP 14). 23. Press [Home] to reach Target selection menu. 24. Press [Exit service] when ready to exit service mode.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

GP 20 NVM Reset
1. Purpose
The NVM Reset procedure is used to recover booklet quality base NVM values for side guides, staple stop gate, fold stop gate, staple
position, back jogger and trim knife zero.
The NVM Reset procedure is used after updating software, replacing the PCB Controller, PCB A, PCB Printer interface, PCB E (BM) or
F (RCT), or when a part affecting the booklet quality has been replaced.
The NVM reset procedure can also be initiated to resolve minor logic problems.
2. Procedure
General procedure to perform NVM reset is described below. Depending on circumstances, exact procedure to retieve NVM values may
vary, see flowcharts further below.
NOTE:
All data in the EEPROM will be cleared including jobs, jam history etc. The only data not cleared are the Staple, Fold, Trim, Cover Feed,
Rotator, Crease and Bleed Trimmer counters.
1.
Enter the service menu (GP 1).
2.
Select target (module) BM.
3.
Select item [NVM].
4.
Record NVM values: BM: Index 2-7 and 11.
5.
Press [Home] to reach Target selection menu.
6.
Select target (module) [RCT].
7.
Select item [NVM].
8.
Record NVM values: RCT: Index 2-4.
9.
Press [Go back] to reach RCT Service Components menu.
10.
Select item [Reset NVM]. Follow on screen instruction.
11.
Press [Reset]. Read/follow on screen instructions. Press [Go back] to reach RCT Service Components menu.
12. Select item [NVM].
13.
Re-enter NVM values RCT: Index 2-4 recorded in step 8.
14.
Press [Home] to reach Target selection menu.
15. Select target (module) [BM].
16.
Select item [Reset NVM]. Follow on screen instruction.
17.
Press [Reset]. Read/follow on screen instructions. Press [Go back] to reach BM Service Components menu.
18. Select item [NVM].
19.
Re-enter NVM values BM: Index 2-7 and 11 recorded in step 4.
20.
Press [Go back] to reach BM Service components menu.
21. Select [Printer] (GP 8).
22.
If present, enable Cover Feeder Module (GP 14).
23.
Press [Home] to reach Target selection menu.
24.
Press [Exit service] when ready to exit service mode.