PRESCRIBE Command Reference SCAP - Set line CAP Format SCAP mode; Parameter mode: line cap mode: 1 = square caps 2 = butt caps 3 = round caps Function The SCAP command determines the shape of line ends (or a line cap) in a path where they are finally stroked. The default caps is butt caps (2). Square caps have square ends which extend one-half of a line width beyond the endpoints of the line. Butt caps are similar to square caps but the caps are flash with the endpoints and do not extend beyond them. Round caps end the lines with semicircular caps with diameters identical to the line width. Square caps (default) Butt caps Round caps File !R! UNIT C; SPD .5; NEWP; CMNT Round-capped on every end; SCAP 3; PMZP 6, 6; SCP; SCP; PDRP 1, -1; RPP; PDRP 1, 1; RPP; PDRP 5, 0; STRK; PAGE; EXIT; 266