Kyocera ECOSYS P5021cdw PRESCRIBE Commands Command Reference Manual Rev 5.1 - Page 308
Shmi
View all Kyocera ECOSYS P5021cdw manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 308 highlights
PRESCRIBE Command Reference SHMI - Set HMI Format SMHI hmi; Parameter hmi: horizontal motion index; in a fixed font, the distance from the center of one character to the center of the next; in a proportionally spaced font, the width of the space character Function The SHMI command sets the HMI. The parameter is measured in the unit value specfied by the UNIT command. File !R! RES; SLM 1; STM 2; EXIT; This line has the default spacing. !R! UNIT C; SHMI .3; EXIT; This line has a slightly wider spacing. !R! SFNT 'TimesNewRoman', 10; SHMI .3; EXIT; Proportional fonts are not influenced. !R! PAGE; EXIT; Printout 298
PRESCRIBE Command Reference
298
SHMI —
Set HMI
Format
SMHI
hmi
;
Parameter
hmi:
horizontal motion index; in a fixed font, the distance from the center of one character to
the center of the next; in a proportionally spaced font, the width of the space character
Function
The SHMI command sets the HMI. The parameter is measured in the unit value specfied
by the UNIT command.
File
!R! RES; SLM 1; STM 2; EXIT;
This line has the default spacing.
!R! UNIT C; SHMI .3; EXIT;
This line has a slightly wider spacing.
!R! SFNT ’TimesNewRoman’, 10; SHMI .3; EXIT;
Proportional fonts are not influenced.
!R! PAGE; EXIT;