Kyocera FS-1350DN PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 378
XBCP 3, set error correction level
View all Kyocera FS-1350DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 378 highlights
PRESCRIBE Command Reference XBCP 3 - set error correction level Format XBCP 3, level; Parameter level: error correction level, integer from 0 to 8 Function The XBCP 3 command sets the error correction level by predetermined values. An illegal value defaults to 0. Note that the execution of XBCP 3 overrides the setting of XBCP 2 and remains valid until RES (reset) or XBCP 0. File To sets the error correction level to level 4: !R! RES; XBCP 3, 4; XBAR;Error correction can also be set by level;ENDB; EXIT; 368
PRESCRIBE Command Reference
368
XBCP 3 —
set error correction level
Format
XBCP 3,
level
;
Parameter
level:
error correction level, integer from 0 to 8
Function
The XBCP 3 command sets the error correction level by predetermined values. An
illegal value defaults to 0. Note that the execution of XBCP 3 overrides the setting of
XBCP 2 and remains valid until RES (reset) or XBCP 0.
File
To sets the error correction level to level 4:
!R! RES;
XBCP 3, 4;
XBAR;Error correction can also be set by level;ENDB;
EXIT;