Kyocera FS-2020D PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 325
Smnt
UPC - 632983014219
View all Kyocera FS-2020D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 325 highlights
SMNT SMNT - Set MoNiTor simulation COLOR Format SMNT monitor-type [,temperature, red-x, red-y, green-x, green-y, blue-x, blue-y, gamma]; Parameters monitor-type: 0 = None 1 = SMPTE 240M 2 = HDTV (sRGB) [default] 3 = Sony Trinitron 4 = Apple RGB 5 = NTSC 6 = KC-RGB 7 = Custom temperature: color temperature 3500, 5000, 5500, 6500 (default), 6740, 7500, 9300 red-x/red-y/... chromaticity coordinates: red-x: number from 0.0 to 3.0 (default = 0.64) red-y: number from 0.0 to 3.0 (default = 0.33) green-x: number from 0.0 to 3.0 (default = 0.30) green-y: number from 0.0 to 3.0 (default = 0.60) blue-x: number from 0.0 to 3.0 (default = 0.15) blue-y: number from 0.0 to 3.0 (default = 0.06) gamma value of gamma correction: number from 1.0 to 3.0 (default = 2.2) Function The SMNT command simulates a particular monitor or a monitor customized by specifying the color temperature, etc. Parameters except monitor-name are enabled only when monitor-name value is 7 (custom). Resetting the printing system or switching emulation modes resets all custom parameters to the default states. The simulation provided by this command is enabled only when the device-dependent color space is in use. 315