Kyocera KM-C3232 PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 365
UOM
View all Kyocera KM-C3232 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 365 highlights
UOM UOM - Unit Of Measurement per dots Format UOM number; Parameter number: 96, 100, 120, 144, 150, 160, 180, 200, 225, 240, 288, 300, 360, 400, 450, 480, 600, 720, 800, 900, 1200, 1440, 1800, 2400, 3600, 7200 Function The UOM command applies only to the printing system models that support the 600 dpi resolution. It defines the unit of measurement in dots per inch for cursor movements. The command requires that the UNIT value be set to D. The default unit of measurement is 300 (dpi). For example, the cursor movement of 50 dots equals 1/6 inches. The command accepts only the above numbers for the unit of measurement. Any other numbers will be ignored when used with this command. File !R! FRPO N8, 1; RES; UNIT C; SFNT "Helvetica-Nr", 9; MZP 5, 5; TEXT "UOM 120; BOX 100, 100;", L; UNIT D; UOM 120; BOX 100, 100; UNIT C; MZP 5, 9; TEXT "UOM 720; BOX 100, 100;", L; UNIT D; UOM 720; BOX 100, 100; PAGE; EXIT; 355