LG 50LN5700 Owners Manual - Page 45
Communication Parameters, Command reference list - contrast ratio
View all LG 50LN5700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
EXTERNAL CONTROL DEVICE SETUP 5 ENEGNLGISH Communication Parameters • Baud rate : 9600 bps (UART) • Data length : 8 bits • Parity : None Command reference list (Depending on model) • Stop bit : 1 bit • Communication code : ASCII code • Use a crossed (reverse) cable. COMMAND1 COMMAND2 DATA (Hexadecimal) COMMAND1 COMMAND2 DATA (Hexadecimal) 01. Power off k 02. Aspect Ratio k 03. Screen Mute k 04. Volume Mute k 05. Volume Control k 06. Contrast k 07. Brightness k 08. Color/ Colour k 09. Tint k 10. Sharpness k 11. OSD Select k 12. Remote Control Lock k Mode a 00 13. Balance k t 14. Color c (p.7) (Colour) x u Temperature 15. ISM d (p.7) Method (Only j p Plasma TV) e 00 to 01 16. Energy Saving j q f 00 to 64 17. Tune Command m a 18. Channel m b g 00 to 64 (Programme) Add/Del(Skip) h 00 to 64 19. Key m c 20. Control m g i 00 to 64 Back Light, Control Panel Light j 00 to 64 21. Input x select (Main) b k 00 to 32 22. 3D (Only x 3D models) t 23. Extended x v l 00 to 01 3D (Only 3D models) m 00 to 01 00 to 64 00 to 64 (p.8) 00 to 05 (p.8) 00 to 01 Key Codes 00 to 64 (p.10) (p.11) (p.11) * Note: During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are not executed and treated as NG.