LG 55EF5K-L User Guide - Page 81
Status Check Command: s v, Daylight Saving Time] Command: s d, Checks whether the Top, Bottom and Main
View all LG 55EF5K-L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
81 ENGLISH 46. Status Check (Command: s v) Checks the current signal of the product. Transmission (s)(v)( )(Set ID)( )(Data)( )(FF)(Cr) Data 02: C heck whether there is a signal 03: The monitor is currently in PM Mode 07: C hecks whether the Top, Bottom and Main temperature sensors are functioning normally. 09: F an Speed 10: R GB Sensing OK/NG (screen fault detection) 16: Check the humidity value 17: C heck the value of the intensity of illumination 18: C heck the status value of the slope of the product Acknowledgment (v)( )(Set ID)( )(OK/NG)(Data)(Data1)(x) Data 02 (when a signal is found) Data1 00: N o signal 01: S ignal present Data 03 (when the monitor is currently in PM mode) Data1 00: S creen is on 01: S creen is off 02: S creen Off Always is activated 03: S ustain Aspect Ratio is activated 04: S creen Off & Backlight On is activated Data 07 (when checking whether the Top, Bottom and Main temperature sensors are working properly) Data1 00: A ll temperature sensors are faulty 01: Top normal, Bottom faulty, Main faulty 02: Top faulty, Bottom normal, Main faulty 03: Top normal, Bottom normal, Main faulty 04: Top faulty, Bottom faulty, Main normal 05: Top normal, Bottom faulty, Main normal 06: Top faulty, Bottom normal, Main normal 07: A ll temperature sensors are normal Data 10(when executing Screen Fault Detection) Data 1 00: Screen Fault Detection result NG 07: Screen Fault Detection result OK * When screen Fault Detection is set to Off or not supported, execution results are rendered "NG." Data 16(for checking the humidity value) Data 1 0~100: Reads the %RH value of the current humidity (indicated as a Hex value). Data 17(for checking the value of the intensity of illumination) Data 1 1~1000: Reads the Lux value of the current intensity of illumination (indicated as a Hex value). Data 18(for checking the status value of the slope of the product) Data 1 00: 0 degrees 01: 90 degrees 02: 180 degrees 03: 270 degrees 04: Fallen forward 05: Fallen backward Data 09(when checking the fan speed) Acknowledgement (v)( )(Set ID)( )(OK/NG)(Data)(Data1_1)(Data1_2) ...(DataN_1)(DataN_2)(x) Data1_1:00~ff: First fan speed top 1 Byte Data1_2: 00~ff: First fan speed bottom 1 Byte ... DataN_1: 00~ff: Nth fan speed top 1 Byte DataN_2: 00~ff: Nth fan speed bottom 1 Byte Fan Speed: Hex 0~2008, Decimal 0~8200 * The data number (N) may vary depending on the model. * This feature may not be available for all models. 47. [Daylight Saving Time] (Command: s d) Sets Daylight Savings Time. Transmission (s)(d)( )(Set ID)( )(Data1)( )(Data2)( ) (Data3)( )(Data4)( )(Data5)( )(Cr) Data1 00: O ff (Data2-5: F F) 01: Start Time 02: End Time Data2 01~0C: January - December Data3 01-06: W eek 1 - 6 * The maximum value of [Data3] may vary depending on the date. Data4 00-06: (Sunday - Saturday) Data5 00-17: 0 0 - 23 hours * If you wish to read the start/end times, enter FF for parameters [Data2] through [Data5]. (Example 1: sd 01 01 ff ff ff ff - Checks the start time. Example 2: s d 01 02 ff ff ff ff - Checks the end time.) * This feature only works when Clock 1 (year/month/day) and Clock 2 (hour/minute/second) have been set. Acknowledgment (d)( )(Set ID)( )(OK/NG)(Data1)(Data2) (Data3)(Data4)(Data5)(x) * This feature may not be available for all models.