LG L6004R Service Manual - Page 13

Possible Trouble 2, Possible Trouble 3

Page 13 highlights

Possible Trouble 2 The compressor does not operate. Troubleshooting Guide Is setting Temp. set lower than Room NO Temp.-0.5°C? YES • Select the setting Temp. to lower Number. Is the voltage No.11 NO of IC01M 0V? YES • Check the RY-COMP. • Check the wiring Diagram. Is the voltage N0.6 of IC01M DC 5V? YES • Exchange IC01M. NO NO Is the Unit for 3 minutes delay? YES • Wait 3 Minutes. • Exchange MAIN PCB Ass'y. Possible Trouble 3 The compressor always operate. Is the wire connection of NO RY-COMP all right? YES • Check the RY-COMP. • Connect LEAD Wire to RY-COMP again. Service Manual 13