ENGLISH ELECTRICAL CONNECTIONS (cont.) IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT GROUNDING TO THE NEUTRAL (WHITE) WIRE Observe all governing codes and local ordinances. ᕡ Disconnect the power supply. 4-WIRE GROUNDED JUNCTION BOX Cable from power supply ᕢ At the circuit breaker box, fuse box or junction box, connect appliance and power supply cable wires as shown. WARNING If connecting to a 4-wire power supply cable electrical system, the appliance frame connected ground wire MUST NOT be connected to the neutral wire of the 4-wire electrical system. Ground Wire Red wires White wire (no connection) Black wires Junction box Green wire (ground) UL-listed conduit connector Cable from cooktop COOKTOP INSTALLATION ᕡ Visually inspect the cooktop for damage. Make sure all cooktop screws are tight (see below for locations). ᕢ Carefully lower the cooktop into the counter- top cutout, making sure not to trap any wires. NOTE: Do not use caulking compound. The cooktop must be removable, should service be required. Screws 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

ENGLISH
27
ELECTRICAL CONNECTIONS
(cont.)
Observe all governing codes and local
ordinances.
±
Disconnect the power supply.
²
At the circuit breaker box, fuse box or junction
box, connect appliance and power supply cable
wires as shown.
WARNING
If connecting to a 4-wire power supply cable
electrical system, the appliance frame
connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT GROUNDING
TO THE NEUTRAL (WHITE) WIRE
4-WIRE GROUNDED JUNCTION BOX
Cable from power supply
Black
wires
White wire
(no connection)
Red
wires
Junction box
UL-listed conduit
connector
Cable from cooktop
Green wire (ground)
Ground
Wire
COOKTOP INSTALLATION
±
Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight
(see below for locations).
²
Carefully lower the cooktop into the counter- top
cutout, making sure not to trap any wires.
NOTE:
Do not use caulking compound. The
cooktop must be removable, should service be
required.
Screws