Step 7: Water Supply Connection, Step 8: Electrical Power Connection - black

Page 31 highlights

Step 7: WATER SUPPLY CONNECTION 1. When connecting, sealing tape or sealing compound should be used to avoid water leaks. 2. Before connecting, turn off the water supply. 3. After fitting the Elbow into the Inlet Valve, slide the Flexible Stainless Tube or Copper Tube into the Elbow. Inlet Valve Elbow Water Supply Tube 4. Tighten the nut and make sure that the line is not kinked or sharply bent. Step 8: ELECTRICAL POWER CONNECTION 1. Before beginning, turn off electrical power to the unit at the circuit breaker. 2. Remove the Junction Cover and then Install the Strain Relief. 3. Twist Wire Connectors tightly on the wires. Wrap each connection with Electrical tape. Junction Cover 4. Check again and make sure that all wires are connected correctly, black to black, white to white, green to green (ground to ground). 5. Replace the Junction Cover. Wire Connector Junction Case Strain Relief - 32 - black to black green to green (ground to ground) white to white

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

- 32 -
- 32 -
Step 7: WATER SUPPLY CONNECTION
1. When connecting, sealing tape or
sealing compound should be
used to avoid water leaks.
2. Before connecting, turn off the water
supply.
3. After fitting the Elbow into the
Inlet Valve, slide
the Flexible
Stainless Tube or Copper Tube
into the Elbow.
4. Tighten the nut
and make sure
that the line is not kinked or
sharply bent.
Inlet Valve
Water Supply Tube
Elbow
1. Before beginning, turn off electrical
power to the unit at the circuit breaker.
2. Remove the Junction Cover and then
Install the Strain Relief.
3. Twist Wire Connectors tightly on the
wires. Wrap each connection with
Electrical tape.
4. Check again and make sure that all
wires are connected correctly, black to
black, white to white, green to green
(ground to ground).
5. Replace the Junction Cover.
Junction Cover
Wire Connector
Junction Case
Strain Relief
black to black
(ground to ground)
green to green
white to white
Step 8: ELECTRICAL POWER CONNECTION