Connecting the Piping
View all LG LMU360CE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Flaring Work and Connection of Piping Check 1. Compare the flared work with the figure by. 2. If a flared section is defective, cut it off and do flaring work again. Smooth all round Inside is shiny without scratches = Improper flaring = Even length all round Connecting the Piping Indoor 1. Prepare the indoor unit's piping and drain hose for installation through the wall. 2. Remove the plastic tubing retainer(see the illustration by) and pull the tubing and drain hose away from chassis. 3. Replace only the plastic tubing holder 1, not the holder 2 in the original position. Inclined Surface Cracked Uneven damaged thickness For right rear piping 1. Route the indoor tubing and the drain hose in the direction of rear right. 2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole. • Do not connect the cable to the indoor unit. • Make a small loop with the cable for easy connection later. 3. Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the uper side can cause drain pan to overflow inside the unit. If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. 22 Multi type Air Conditioner Drain hose Drain hose Tape Connecting pipe Drain hose Connecting cable Connecting cable Drain hose Loop Gas side piping Liquid side piping