INSTALLATION 9 EN INSTALLATION Electrical Data Power cord may include a current interrupter device. TEST and RESET buttons are provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. for 120 V RESET TEST RESET TEST Model Use Wall Receptacle Power Supply LW2516ER LW2521ERSM Standard 240 V, 3-wire grounding receptacle rated 20 A / 240 VAC / 60 Hz Use 20 A, time delay fuse or 20 A, circuit breaker. Model Use Wall Receptacle Power Supply LW1516ER LW1521ERSM Standard 120 V, 3-wire grounding receptacle rated 15 A / 120 VAC / 60 Hz Use 15 A, time delay fuse or 15 A, circuit breaker. for 240 V RESET TEST Model Use Wall Receptacle Power Supply LW1816ER LW1821ERSM Standard 240 V, 3-wire grounding receptacle rated 15 A / 240 VAC / 60 Hz Use 15 A, time delay fuse or 15 A, circuit breaker. WARNING ● This appliance should be installed in accordance with the National Electrical Code. ● Use of extension cords could cause serious injury or death. - Do not use an extension cord with this window air conditioner. - Do not use surge protectors or multi-outlet adapters with this window air conditioner. ● Never push the TEST button during operation. Doing so can damage the plug. - Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected before further use. CAUTION ● The conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded. Periodically examine the cord for any damage. Do not use this product in the event the shields become exposed. Avoid shock hazard. This unit cannot be user-serviced. Do not open the tamperresistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

9
INSTALLATION
EN
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device.
TEST
and
RESET
buttons are provided
on the plug case. The device should be tested on
a periodic basis by first pressing the
TEST
button
and then the
RESET
button. If the
TEST
button
does not trip or if the
RESET
button will not stay
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
for 240 V
RESET
TEST
Use Wall Receptacle
Model
LW1816ER
LW1821ERSM
Power Supply
WARNING
This appliance should be installed in
accordance with the National Electrical
Code.
Use of extension cords could cause serious
injury or death.
- Do not use an extension cord with this
window air conditioner.
- Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
Never push the
TEST
button during
operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this
plug. If this device trips, the cause should
be corrected before further use.
CAUTION
The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamper-
resistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
Standard 240 V, 3-wire
grounding receptacle
rated 15 A / 240 VAC /
60 Hz
Use 15 A, time
delay fuse or
15 A, circuit
breaker.
Use Wall Receptacle
Model
LW1516ER
LW1521ERSM
Power Supply
Standard 120 V, 3-wire
grounding receptacle
rated 15 A / 120 VAC /
60 Hz
Use 15 A, time
delay fuse or
15 A, circuit
breaker.
for 120 V
RESET
TEST
RESET
TEST
Use Wall Receptacle
Model
LW2516ER
LW2521ERSM
Power Supply
Standard 240 V, 3-wire
grounding receptacle
rated 20 A / 240 VAC /
60 Hz
Use 20 A, time
delay fuse or
20 A, circuit
breaker.