LG MB-387W Service Manual - Page 16

K. Pcb Assembly Removal, L. Interlock System

Page 16 highlights

K. PCB ASSEMBLY REMOVAL 1) Remove the control panel assembly from the cavity. (Refer to control panel assembly removal on previous page.) 2) Remove screws which hold the PCB SUB ASS'Y to the control panel. 3) Disconnect the flat cable from the PCB SUB ASS'Y and take off the PCB SUB ASS'Y. L. INTERLOCK SYSTEM 1) INTERLOCK MECHANISM The door lock mechanism is a device which has been specially designed to eliminate completely microwave activity when the door is opened during cooking and thus to prevent the danger resulting from the microwave leakage. 2) MOUNTING OF THE PRIMARY/MONITOR/ SECONDARY SWITCHES TO THE LATCH BOARD ADJUSTMENT DIRECTION PRIMARY SWITCH MONITOR SWITCH SECONDARY SWITCH 3) INSTALLATION AND ADJUSTMENT OF THE LATCH BOARD TO THE OVEN ASSEMBLY • Mount the latch board to the oven assembly. • Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed. • Tighten the mounting screw. • Check for play in the door by pushing the door release button. Door movement should be less than 0.5 mm. (1/64 inch) Don't push the door release button while making adjustment. Make sure that the latch moves smoothly after adjustment are completed and that the screws are tight. Make sure the primary, monitor, and secondary switches operate properly by following the continuity test procedure. FIG. 1 CAUTION: CHECK THE CORRECT POSITION MAGNETRON H.V. TRANSFORMER PRIMARY 5-6 H.V.FUSE H.V. DIODE H.V. CAPACITOR

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

K. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASS’Y to
the control panel.
3) Disconnect the flat cable from the PCB SUB
ASS’Y and take off the PCB SUB ASS’Y.
L. INTERLOCK SYSTEM
1) INTERLOCK MECHANISM
The door lock mechanism is a device which has
been specially designed to eliminate completely
microwave activity when the door is opened during
cooking and thus to prevent the danger resulting
from the microwave leakage.
2) MOUNTING OF THE PRIMARY/MONITOR/
SECONDARY SWITCHES TO THE LATCH
BOARD
3) INSTALLATION AND ADJUSTMENT OF THE
LATCH BOARD TO THE OVEN ASSEMBLY
• Mount the latch board to the oven assembly.
• Adjust the latch board in the arrow direction so that
oven door will not have any play in it when the door
is closed.
• Tighten the mounting screw.
• Check for play in the door by pushing the door
release button. Door movement should be less
than 0.5 mm. (1/64 inch)
Don't push the door release button while making
adjustment. Make sure that the latch moves
smoothly after adjustment are completed and that
the screws are tight. Make sure the primary, monitor,
and secondary switches operate properly by
following the continuity test procedure.
5-6
PRIMARY
SWITCH
SECONDARY
SWITCH
ADJUSTMENT
DIRECTION
MONITOR
SWITCH
CAUTION: CHECK THE CORRECT POSITION
MAGNETRON
H.V. TRANSFORMER
PRIMARY
H.V. CAPACITOR
H.V.FUSE
H.V.
DIODE
FIG. 1